background image

X-SENSE 

CO03D-W 

Wireless Interlinked Carbon Monoxide Alarm 

 

 

 

 

 

 

Содержание Link+ CO03D-W

Страница 1: ...X SENSE CO03D W Wireless Interlinked Carbon Monoxide Alarm...

Страница 2: ...lectrochemical sensor designed for domestic use Please note that this device does not detect smoke heat flames or anyhazardous gas other than carbon monoxide even though carbonmonoxide can be generate...

Страница 3: ...5 V AA Batteries 2 Screws 2 Anchor Plugs 1 User Manual 2 Carbon Monoxide Safety Stickers Product Features LCD Display Fault Low Battery Indicator Yellow LED Alarm Indicator Red LED Power Indicator Gr...

Страница 4: ...programmed to sound an alarm at the following CO concentrations within the time periods listed 70 ppm for 60 240 minutes 150 ppm for 10 50 minutes and 400 ppm for 4 15 minutes When CO is detected and...

Страница 5: ...22 hours by pressing the test button This end of life silence feature can only be used for a total of 30 days After 30 days the end of life signal cannot be silenced During this end of life silence p...

Страница 6: ...nd make sure that they are both turned on to ensure successful connection NOTE Install the batteries correctly to turn on CO03D W To learn how to turn on different models of wireless interlinked alarm...

Страница 7: ...NOTES 1 The alarm will enter the searching mode or the pairing mode for 60 seconds with the red LED flashing After 60 seconds repeat step 2 to connect the alarms If needed press the TEST HUSH button o...

Страница 8: ...rm be tested during the weekly test Test a single CO alarm Test all interconnected CO alarms Action Press the TEST HUSH button Hold down theTEST HUSH button Indication The LCD will turn on and display...

Страница 9: ...e appliance is in a room not normally used such as a boiler room the CO alarm should be placed just outside of this room so that the alarm can be heard more easily 1 Installing a CO Alarm in a Room wi...

Страница 10: ...room with a fuel burning appliance Figure 1 In rooms with sloped ceilings the CO alarm should be located at the high side of the room 2 Installing the CO Alarm in a Bedroom or Room Without a Fuel Bur...

Страница 11: ...y areas 2 Where there is the possibility of smoke or fumes under normal operating circumstances 3 In poorly ventilated kitchens garagesand furnace rooms Keep the CO alarms at least5 feet 1 5 m from po...

Страница 12: ...rd the wall and the curved hole at the lower position 2 Mark 2 screw holes according to the holes on the mounting bracket then remove the bracket and drill the screw holes to a depth of 1 18 in 30 mm...

Страница 13: ...sh 3 times sequentially every 1 5 seconds 3 long beeps every 1 5 seconds Dangeroussmoke concentration is detected by the initiating unit in the network Please find the initiating unit and take action...

Страница 14: ...yellow LED indicator flashes 3 times every 60 seconds None Silence mode during the end of the cycle After 22 hours the unit will exit silence mode The green LED indicator flashes 3 times None Exiting...

Страница 15: ...larm are triggered in the network at the same time the alarm signal of the smoke alarm will take priority over that of the CO alarm This alarm has a relay function that extends the wireless interconne...

Страница 16: ...uated the area or has access to fresh air Do not re enter the house until it has been aired out and your alarm remains under normal condition If it is not possible to move outside stay close to an ope...

Страница 17: ...detect CO that reaches the sensor CO may be present in other areas Doors or other obstructions may affect the rate at which CO reaches the CO alarm For this reason if bedroom doors are usually closed...

Страница 18: ...ioning The wireless signal might be blocked or out of range The yellow LED flashesonce every 60 seconds with one beep The battery is low Replace the battery immediately The yellow LED flashestwice eve...

Страница 19: ...equipment This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any int...

Отзывы: