background image

TROUBLESHOOTING 

INFORMATION

RS3200PLUS SECURITY SYSTEM

CONNECTOR1

CIRCUIT

MEASUREMENT

1 - Ground  

SUB +B Power (Dome)  

Always Approx. 12V 

2 - Ground  

+B Power (Dome)  

Always Approx. 12V 

3  

Trunk Key Input  

Continuity when key turned to open 

4 - Ground  

Key Unlock Warning Input  

Continuity when key is in the ignition switch 

5  

N/C  

6 - Ground  

 

7 - Ground  

G.B.S. Input  

0V (Pulsed) when window hit 

8 - Ground  

N/C  

9 - Ground  

N/C  

10  

MPX signal  

11 Ground  

ECU Ground  

12 - Ground  

LED Output  

Continuity 

Approx. 1.8V when LED on, 0V when LED off 0V during trig-
gering 

Starter Cut Input  

Approx. 12V when ignition switch at ST position, 0V during 
triggering 

IG Input  

Approx. 12V 

  

N/C  

when ignition switch is in ON position 

13 - Ground  

14 Ground  

15

16  

N/C  

N/C  

N/C  

N/C 

17

18

19

20

N/C 

N/C  

N/C

21  

22  

N/C  

23  

N/C  

24  

N/C  

25  

Starter Cut Output  

Approx 12V when ignition switch is in ON position 

26 - Ground  

Содержание RS3200PLUS

Страница 1: ... Ground G B S Input 0V Pulsed when window hit 8 Ground N C 9 Ground N C 10 MPX signal 11 Ground ECU Ground 12 Ground LED Output Continuity Approx 1 8V when LED on 0V when LED off 0V during trig gering Starter Cut Input Approx 12V when ignition switch at ST position 0V during triggering IG Input Approx 12V N C when ignition switch is in ON position 13 Ground 14 Ground 15 16 N C N C N C N C 17 18 19...

Страница 2: ...ng Disarming Common causes for this complaint Mis spliced Key Unlock Warning wire mis spliced door courtesy wire connectors not plugged in securely Fuse or shortpin not installed in vehicle blown fuse in RS3200PLUS harness does not apply to all vehicles RS3200PLUS SECURITY SYSTEM What to Ask and Verify What to Check Do the vehicle s door locks work with the door switches or key Yes Check and corre...

Страница 3: ... case LIQUID DAMAGE ITEMS ARE NOT COV ERED UNDER WARRANTY No If no continuity there is a wire harness problem Fix as necessary Complaint No Horn Function Common causes for this complaint Mis spliced Horn wire connectors not plugged in securely blown Horn fuse RS3200PLUS SECURITY SYSTEM What to Ask and Verify What to Check Does the horn switch in the vehicle work Yes Check and correct the horn wire...

Страница 4: ...d reconnect the vehicle s connectors then check the tail light function again If they work check the RS3200PLUS harness If not the problem is vehicle related applies to some vehicles Complaint LED Inoperative No blinking No turning on Common causes for this complaint Mis spliced LED wire mis spliced door courtesy wire connectors not plugged in securely RS3200PLUS SECURITY SYSTEM What to Ask and Ve...

Страница 5: ...onnector not plugged in securely RS3200PLUS SECURITY SYSTEM What to Ask and Verify What to Check Does the duplicate panic mode operation work Yes Check the panic signal wire s splice location Does not apply to all vehicles Verify the splice connector was applied properly Confirm the panic signal wire with terminal location Check door lock control connector is plugged in securely No No Problem ...

Отзывы: