COMMUNICATION MANUAL
GXE600 SERIES
TDKLambda
<Page>
78/79
Supplementary
1. Communication configuration switch
It is possible to set and check all communication configurations of the GXE series by use communication lines.
GXE series don't have display function of the communication configuration.
When disconnecting GXE from communication bus line due to changing system configuration, etc., you might miss the
communication configuration of it. If the communication configuration switch is disabled(DIS) and you apply input to GXE,
GXE start with default communication configuration.
!
To prevent electric shock, operate the switch after enough time has elapsed from input shutdown.
*Default Communication Configuration
Item
Default Setting
Slave ID
ID : 1
Baud Rate
19200 bps
Parity
Even parity
Stop bit
1 bit
By connecting to GXE with one to one by use this communication configuration, you can confirm or change to communication
configuration of GXE.
!
If the switch is disable(DIS) and plural GXEs connected to the bus, you cannot correct communication.
Step1: After sufficient time has elapsed since the input is cut off, switch the communication configuration switch
to disable(DIS). Refer to the figure below for the location and direction of the switch.
Step2: Read the communication configuration related registers and check the setting contents.
Step3: Modify the register settings related to communication settings as necessary and update them.
Step4: After sufficient time has elapsed since the AC input was cut off, you switch the communication configuration switch
to enable(EN).
*/A : For the option model with cover, slide the SW81 from the rectangle hole
at side surface by non conductive tweezers etc..
Communication Configuration Swtch (SW81)
ENABLE
DISABLE