![TDK-Lambda GXE600 Series Скачать руководство пользователя страница 41](http://html2.mh-extra.com/html/tdk-lambda/gxe600-series/gxe600-series_communications-manual_4197170041.webp)
COMMUNICATION MANUAL
GXE600 SERIES
TDKLambda
<Page>
41/79
#
3
Re gist e r Nam e
PVCC ReferenceConfiguration
Data Type
Register Function
Starting Address
Qty
Non-volatile
Holding
Selection of analog or digital reference value
1
Yes
1) Register Details
This register is the setting register related to the output reference value. GXE has two output reference,
which are PV / CC terminal reference (Analog PV / CC) and PV / CC communication reference (Digital PV / CC).
Output reference can be selected with this register.
Configuration data is retained even when input is cut off.
・Register configuration value
Bit
Function
Digital PV/CC
Analog PV/CC
Factory setting
0
Selection of output voltage reference
1
0
0
1
Selection of output current reference
1
0
0
2 - 15
Reserved
-
-
0
* Write '0' to the reserved bit. Writing '1' is ignored.
Digital PV / CC is not referenced when analog PV / CC is selected.
Conversely, Analog PV / CC is not referenced when Digital PV / CC is selected.
This register is just a function to select the input source of the PV / CC reference value.
Change input source according to setting of this register, when changing PV / CC reference value.
Refer to the instruction manual, for Analog PV / CC.
2) Register Read
R eques t PD U
Read Holdings.
Field
Byte
Value
Function code
1
0x 03
Starting Address
2
101 (0x0065)
Quantity of Registers
2
(0x0000)
R es pons e PD U
Read Holdings.
Field
Byte
Value
Function code
1
0x 03
Byte count
1
2 (2 x 1)
Registers value
2
Reading data.
E rror PD U
Read Holdings.
Field
Byte
Value
Function code
1
0x 83
Exception code
1
0x02 / 0x04
101
(0x0065)