COMMUNICATION MANUAL
GXE600 SERIES
TDKLambda
<Page>
21/79
#
Holding Register
Starting
Address
Qty Function
14
PF mode
112
1
(0x0070)
15
PF Count
113
1
(0x0071)
16
Period of auto-recovery
114
1
(0x0072)
17
Clear Alarm History
115
1
(0x0073)
18
Slave Address
*
200
1
(0x00C8)
19
SCI Baud Rate
*
201
1
Baud Rate Configuration.
(0x00C9)
20
SCI Parity
*
202
1
Parity Bit Configuration.
(0x00CA)
21
Scratch Pad1
300
15
(0x012C)
Scratch Pad2
320
15
(0x0140)
*
a. When re-input.
b. When query is issued with diagnostic function subcode 0x0001.
Therefore it does not become influence immediately even if setting is changed.
It is a register that customers can freely store data.
Up to 30 characters of data can be stored in ASCII
characters.
Valid as data other than readable characters.
It influences setting change in the slave Address, the Baud Rate and the parity setting register at the time of
initialization of a GXE communication port.
The timing to initialize the communication port is as follows.
"Power Fail" detection mode setting.
It is possible to select "Power Fail" detection target
either "Output voltage" or "Output current".
"Power Fail" detection sensitivity setting. It is possible to
specify "PF" sensitivity in units of milliseconds.
Automatic recovery time setting when protection is
activated. It is possible to specify "Automatic recovery
time" in units of 10 milliseconds.
Alarm history clear register.
This register is write-only. An exception response is
returned when reading this register.
Software Slave Address. Address : 1 to 247 is available.
Broadcast query is invalid. This is to avoid duplicate
address setting.