COMMUNICATION MANUAL
GXE600 SERIES
TDKLambda
<Page>
34/79
#
10
Re gist e r Nam e
Firmware Version
Data Type
Register Function
Starting Address
Qty
Non-volatile
Input
Indicate the Firmware version.
1
Yes
1) Register Details
This register is 4-digit BCD (Binary coded Decimal) data of 16 bits and corresponds to the version number of the power
supply installed firmware.
The upper 1 digit indicates the integer part, and the lower 3 digits indicate the decimal part.
Firmware version is retained even when input is cut off.
Example
FW Version
Value
1.001
0x1001
2.054
0x2054
2) Register Read
R eques t PD U
Read Inputs.
Field
Byte
Value
Function code
1
0x 04
Starting Address
2
1000 (0x03E8)
Quantity of Registers
2
1 (0x0001)
R es pons e PD U
Read Inputs.
Field
Byte
Value
Function code
1
0x 04
Byte count
1
2 (2 x 1)
Registers value
2
Reading data.
E rror PD U
Read Inputs.
Field
Byte
Value
Function code
1
0x 84
Exception code
1
0x02
1000
(0x03E8)