![TDK-Lambda GXE600 Series Скачать руководство пользователя страница 20](http://html2.mh-extra.com/html/tdk-lambda/gxe600-series/gxe600-series_communications-manual_4197170020.webp)
COMMUNICATION MANUAL
GXE600 SERIES
TDKLambda
<Page>
20/79
4.2 Holding Register List
Holding Registers are readable / writable 16-bit data registers.
Mainly, Holding Registers has settable data.
Each setting value is retained even if the GXE input is shut down unless otherwise specified.
Broadcast is invalid for read queries.
Data read is possible with function code: 0x03.
Data write is possible with function code: 0x06 or 0x10.
Data read / write is possible with function code: 0x17.
#
Holding Register
Starting
Address
Qty Function
1
Remote On/Off
0
1
Communication remote On/Off control.
(Volatile)
(0x0000)
Value is volatile.
Remote On/Off
5
1
Communication remote On/Off control.
(Non-Volatile)
(0x0005)
Value is non-volatile.
2
Remote On/Off configuration
100
1
(0x0064)
3
101
1
(0x0065)
4
Protect Converter
102
1
Configuration
(0x0066)
5
PV Digital Reference
103
1
Digital reference value of output voltage.
(0x0067)
Normalized Q10 volts
6
CC Digital Reference
104
1
Digital reference value of output current.
(0x0068)
Normalized Q10 amps
7
Over Voltage Threshold
105
1
Threshold value of output over voltage.
(0x0069)
Normalized Q10 volts
8
Over Current Threshold
106
1
Threshold value of output over current.
(0x006A)
Normalized Q10 amps
9
Rising Time of Output Voltage
107
1
Voltage slew rate at output start
(0x006B)
10
Rising Time of Output Current
108
1
Current slew rate at output start
(0x006C)
11
109
1
(0x006D)
12
110
1
(0x006E)
13
PF Threshold
111
1
(0x006F)
Continued on next page
Threshold value of Power Fail signal.
The threshold is specified as a percentage of the PV /
CC reference value as 100%.
The PV / CC reference value is selected in the "PF
mode" register.
Slew rate of the PV reference value when the PV
reference is changed.
Slew rate of the CC reference value when the CC
reference is changed.
Changing Time of Output
Current at steady state
Changing Time of Output
Voltage at steady state
Protection mode configuration. It is possible to select
either "Auto Recovery" or "Latch stop".
PVCC Reference
Configuration
Remote On/Off control configuration. It is possible to set
remote control ON/OFF mode and remote control ON/OFF
terminal input sensitivity.
It is possible to select either "Analog PV/CC Reference"
or "Digital PV/CC Reference".