COMMUNICATION MANUAL
GXE600 SERIES
TDKLambda
<Page>
28/79
#
5
Re gist e r Nam e
Converter Operation Time
Data Type
Register Function
Starting Address
Qty
Non-volatile
Input
Monitor value of cumulative operating time
2
Yes
1) Register Details
This register is the value of the cumulative operating time.
Operation time is incremented every second while power is being output.
Register value is signed 32-bit integer data value (unit : Second).
Cumulative operating time is retained even when input is cut off.
Data Type
Measurement Range
Accuracy
Integer notation ( 32bit )
Over 20 years
± 2 %
*
*
If the power output is less than 1 second, it will not be added to the cumulative operating time.
Because measurement resolution is 1 second.
Example : Response PDU when cumulative operating time is "19088743" seconds (About 221 days)
19088743d = 0x01234567
2) Register Read
R eques t PD U
Read Inputs.
Field
Byte
Value
Function code
1
0x 04
Starting Address
2
4 (0x0004)
Quantity of Registers
2
2 (0x0002)
R es pons e PD U
Read Inputs.
Field
Byte
Value
Function code
1
0x 04
Byte count
1
4 (2 x 2)
Registers value
4
Reading data.
E rror PD U
Read Inputs.
Field
Byte
Value
Function code
1
0x 84
Exception code
1
0x02/0x04
4
(0x0004)
FC
Bytes
D0
D1
D2
D3
0x04
0x04
0x01
0x23
0x45
0x67