COMMUNICATION MANUAL
GXE600 SERIES
TDKLambda
<Page>
38/79
#
2
Re gist e r Nam e
Remote On/Off configuration
Data Type
Register Function
Starting Address
Qty
Non-volatile
Holding
Remote On/Off control configuration
1
Yes
1) Register Details
This is the configuration register for remote On/Off control .
It is possible to change remote on/off control mode and input sensitivity of the remote on/off control terminal input.
Configuration data is retained even when input is cut off.
・Register configuration value
Byte
Function
Max
Min
Factory setting
LSB
Remote control mode
4
0
0
Terminal input sensitivity
100
0
10
*An exception response (Exception code: 0x03) is returned when writing values outside the range.
・Remote control mode
Two remote control signals for GXE are available: the remote control terminal input of CN84 and the communication input.
Select one suitable for system.
Value
Description
Terminal input is used as remote control signal. Communication input is not referenced.
Refer to the instruction manual for details of remote on/off control using terminal input.
Remote On/Off (Volatile) is used as remote control signal.
Remote On/Off (Non-Volatile) and Terminal input are not referenced.
Remote On/Off (Non-Volatile) is used as remote control signal.
Remote On/Off (Volatile) and Terminal input are not referenced.
The following table shows the relationship between remote control signal and GXE output in each remote control mode.
Terminal input
Communication
Volatile
Non-Volatile
Enable
Disable
OFF
x
x
OFF
ON
x
x
ON
Disable
Enable
x
OFF
x
OFF
(Volatile)
x
ON
x
ON
Disable
Enable
x
x
OFF
OFF
(Non-Volatile)
x
x
ON
ON
Enable
Enable
OFF
x
(Volatile)
ON
x
OFF
x
ON
x
ON
Enable
Enable
x
OFF
(Non-Volatile)
x
ON
x
OFF
x
ON
ON
x : It is not referred.
OFF
ON
OFF
4
OFF
OFF
ON
3
1
2
Value
0
(Factory setting)
Output
MSB
100
(0x0064)
Communication
0
(Factory setting)
1
2
3
4
Terminal
input
The logical AND of the Terminal input and the Remote On/Off (Volatile) is used as the remote control
signal. Remote On/Off (Non-Volatile) is not referenced.
The logical AND of the Terminal input and the Remote On/Off (Non-Volatile) is used as the remote
control signal. Remote On/Off (Volatile) is not referenced.
Remote control mode