Re gist e r Nam e
Serial number of Product
Data Type
Register Function
Starting Address
Qty
Non-volatile
Input
Strings of device serial number. [ASCII]
8
Yes
1) Register Details
This register is the serial number registered in GXE, and it is written in ASCII.
Handle register data as character array of 8 bit data x 16.
Valid as "Serial number" is data from the beginning to the terminating character [NULL 0x00].
Serial number is retained even when input is cut off.
2) Register Read
R eques t PD U
Read Inputs.
Field
Byte
Value
Function code
1
0x 04
Starting Address
2
520 (0x0208)
Quantity of Registers
2
8 (0x0008)
R es pons e PD U
Read Inputs.
Field
Byte
Value
Function code
1
0x 04
Byte count
1
16 (2 x 8)
Registers value
16
Reading data.
E rror PD U
Read Inputs.
Field
Byte
Value
Function code
1
0x 84
Exception code
1
0x02/0x04
520
(0x0208)