3. Connecting power supply and external components
1
Power Supp ly
Connect the power supply with the “power supply” port and the socket. During self-initialization
the MasterControl displays the version number of its software. As soon as the device is ready to
operate, the main menu appears.
2
Driving booster
To use your digital control you need to connect at least one booster to the “Driving booster” port.
Every Märklin**-compatible booster or booster for the DCC system can be used. Please read the
booster manual!
Please note: Both types of boosters differ regarding short circuit polarity. Yet to be able to use
both types of boosters, the short circuit polarity can be set on the MasterControl. As this setting
applies to all connected boosters, only one type of booster may be connected to your
MasterControl.
Section 11: Background information
Pin ass ignment of the booster’s interfaces
1 Short circuit feedback
2 Ground
3 no function
4 Booster „on / off“
Connector of a Märklin**-
Connector of a DCC-
5 Data
compatible booster
compatible booster
3
Breaking booster
If you want to control breaking distances using a separate booster, you have to connect it to the
“Breaking booster” port. Every Märklin**-compatible booster or booster for the DCC system can
be used. The short circuit polarity also applies to the breaking booster, which thus must be of the
same type as your driving booster.
1
2
3
4
5
6
7
8
1 Power supply
2 Driving booster
3 Breaking booster
4 s88 module
5 DCC programming track
6 Serial interface
7 USB interface
E D C
Содержание MasterControl 40-01007
Страница 4: ...English MasterControl Page 0 2...
Страница 8: ...English MasterControl Page 1 4...
Страница 14: ...English MasterControl Page 4 2...
Страница 18: ...English MasterControl Page 5 4...
Страница 40: ...English MasterControl Page 6 22...
Страница 48: ...English MasterControl Page 7 8...
Страница 50: ...English MasterControl Page 8 2...