background image

MasterControl

English

Page 5.1

5. Features of your MasterControl

MasterControl

You can use your MasterControl to

 

enter parameters of the digital control and to

 

control operation on your whole model railway layout.

Locomotive database

The MasterControl has its own database to store parameters you apply  to  a  locomotive’s  address,
which are:

 

data format,

 

amount of speed levels and

 

(locomotive’s) name

 

Section 6.1. Adjusting parameters in the locomotive menu

Data formats

The MasterControl is a multi protocol control for your  model  railroad  and  capable  of  sending  data
in the following formats:

 

Motorola I („old“ Motorola format)

 

Motorola II („new“ Motorola format)

 

DCC (complying to NMRA standards)

  Section 11. Background information

RailCom

The MasterControl supports the  revertive  standard  RailCom.  The  MasterControl  allows you  to  enter
commands to read out the CV values of decoders compatible to RailCom.

  Section 11.3. RailCom

27 speed levels w ith the Moto rola fo rmat

The Motorola format  standardly  supports  14  speed  levels.  Your  MasterControl  additionally  offers
two methods to extend those speed levels to 27.

Speed  level  mode  27a:  Some  decoders  support  27  speed  levels  using  the  so  called  interspeed
levels.  To  reach  an  interspeed  level  you  switch  to  a  higher  speed  level  and  immediately  switch
back.  A  power  failure  will  cause  the  loss  of  this  speed  information  data.  Your  MasterControl
simulates those  27  speed  levels  and  shows  them in  the  display.  The  MasterControl  creates  the
interspeed levels by regularly switching to a higher speed level for a short  time. This  ensures that
the speed levels are correctly set even after a power failure. Normally,  the  change  between  speed
levels is not visible.

Speed  level  mode  27b:  Using  free  bit  combinations  in  the  function’s  double  bit  helps  realizing
proper  27  speed  levels.  The  decoder  must  support  this.  When  controlling  locomotive  decoders
that only support 14 speed  levels  or  the  speed  level  mode  27a  with  speed  level  mode  27b,  only
every second set speed level actually changes speed.

Содержание MasterControl 40-01007

Страница 1: ...n Information and tips www tams online de Warranty and service Tams Elektronik GmbH Rupsteinstra e 10 D 30625 Hannover fon 49 0 511 55 60 60 fax 49 0 511 55 61 61 e mail modellbahn tams online de 10 2...

Страница 2: ...n Information and tips www tams online de Warranty and service Tams Elektronik GmbH Rupsteinstra e 10 D 30625 Hannover fon 49 0 511 55 60 60 fax 49 0 511 55 61 61 e mail modellbahn tams online de 10 2...

Страница 3: ...on and serial number 6 21 6 8 Exit 6 21 7 Operation 7 1 7 1 Switching track power on and off 7 1 7 2 Driving locomotive and function decoders 7 2 7 3 Double traction 7 5 7 4 Driving solenoid accessory...

Страница 4: ...English MasterControl Page 0 2...

Страница 5: ...s of the EasyControl and is the central input device for all parameters of the model railroad control The MasterControl also has it s own database to store all settings Section 5 Features of your Mast...

Страница 6: ...ooster recognizes a short circuit too high power consumption it calls the MasterControl The MasterControl then switches off the booster and displays a warning 9 Breaking distance booster Through the o...

Страница 7: ...for other 8 Driving booster 2 Power supply bus systems 9 Breaking distance 3 Non central control 6 BusControl booster devices 10 s88 Module 4 SwitchControl 7 DCC programming track 11 PC 5 6 4 3 7 1 3...

Страница 8: ...English MasterControl Page 1 4...

Страница 9: ...ench 4 for Dutch Saftey instructions EayControl should only be used in concordance with these instructions It is not suitable for use by children under 14 Incorrect use can be dangerous In particular...

Страница 10: ...tep Explanations 1 Overview of the display and controls of the MasterControl Section 4 2 Connecting booster and power supply Section 3 3 Switching on AC power Section 7 1 4 Overview of the parameter s...

Страница 11: ...circuit polarity can be set on the MasterControl As this setting applies to all connected boosters only one type of booster may be connected to your MasterControl Section 11 Background information Pi...

Страница 12: ...Only DCC decoders can be programmed using the DCC programming track port Motorola decoders featuring online programming can be programmed on your layout or on an oval track which is connected to the...

Страница 13: ...it an input can be confirmed or during operation mode the driving direction can be changed The MasterControl and LokControl look alike To distinguish between them the speed control knob has different...

Страница 14: ...English MasterControl Page 4 2...

Страница 15: ...ilCom 27 speed levels with the Motorola format The Motorola format standardly supports 14 speed levels Your MasterControl additionally offers two methods to extend those speed levels to 27 Speed level...

Страница 16: ...This way the EasyControl makes it possible to operate locomotives with Motorola and DCC decoders at the same time Creating double tractions Assigning names to locomotives additionally to assigning add...

Страница 17: ...ction 7 6 Resetting your system Saving and restoring your layout status The layout status can be saved at any time Every setting of any active locomotive and function decoders will be saved including...

Страница 18: ...English MasterControl Page 5 4...

Страница 19: ...on both methods Whenever you read press ok to confirm your input pressing the speed control knob is also possible Display Action Button Call the menu Press 0 menu Navigating forward on the same menu l...

Страница 20: ...ayout status 3 2 Restore layout status 4 1 Mode 128 speed levels 4 2 Mode speed controller 4 3 s88 settings 4 1 1 S 88 module 4 1 2 S 88 module test 4 4 Delete the configuration 4 5 Booster configurat...

Страница 21: ...polarity Baud rate of the serial interface 2400 Settings Interface baud rate Data format of points points format Motorola format Settings Points Format Min switching time for points 100 ms Settings P...

Страница 22: ...Return to normal operation mode by pressing esc The submenu enables you to Search for a locomotive s name in the database and select it to operate Individually apply or change parameters for each dec...

Страница 23: ...ve s address Name 99 EMMA or Name 99 ok Possible actions To change enter a name press ok Navigate to another menu point by turning the speed control knob Go back to the main menu level by pressing esc...

Страница 24: ...r menu point of the submenu level 1 by turning the speed control knob Go back to the main menu level by pressing esc FS128 1 1 Possible actions Choose the mode for speed level mode 128 by turning the...

Страница 25: ...value of the variable is not read from the decoder Please note Each DCC decoder is designed for special modes of programming To find out which mode your decoder supports please read the manual Section...

Страница 26: ...avigate to another menu point of the submenu level 1 by turning the speed control knob Go back to the main menu by pressing esc Primary address 103 The MasterControl automatically reads the decoder s...

Страница 27: ...ister value on t he right Possible actions Reading a register Enter register number on the keypad only possible if the cursor is centred on the register number field and confirm input with ok The save...

Страница 28: ...bmenu level 1 by turning the speed control knob Go back to the main menu by pressing esc RailCom CV 29 Possible actions Reading out the CV of a vehicle decoder Enter the no of the CV on the keypad and...

Страница 29: ...b Go back to the operation mode by pressing esc Save layout status ok Possible actions To save layout status press ok To restore layout status turn the speed control knob until Restore layout status i...

Страница 30: ...actions To navigate to submenu level 2 press ok Navigate to another menu point in submenu level 1 by turning the speed control knob Go back to the main menu by pressing esc Mode for speed level mode 1...

Страница 31: ...speed control knob further counterclockwise shows no effect In DC speed controller mode both turning the speed control knob clockwise and counterclockwise effect an increase of the speed level When t...

Страница 32: ...ayed check results press 0 menu Differences between the displayed status and the current status of an s88 module point to errors concerning your s88 bus your s88 module or parts of your model railway...

Страница 33: ...thout saving changes Hint The use M rklin compatible boosters requires setting the short circuit polarity to positive and for DDC compatible boosters to negative Short c sens 100 ms ok Possible action...

Страница 34: ...00 and can t be changed Making settings for solenoid accessory decoders Points config ok Possible actions To set the points format press ok Navigate to another menu point in submenu level 1 by turning...

Страница 35: ...up of four points and ok To set the points format for this group press ok Navigate to another menu point in submenu level 1 by turning the speed control knob Go back to the main menu by pressing esc P...

Страница 36: ...anges Hints When setting a certain minimum switching time you can switch points by quickly tapping the function key although the points need a longer switching time max switch time 5 0 s ok Possible a...

Страница 37: ...andard settings for Motorola is 14 speed levels and for DCC 28 speed levels Using the locomotive menu you can set a different data format and or another amount speed levels Setting duration of the sig...

Страница 38: ...sible adjustments 0 off The Railcom support is switched off 1 Tailbits There will be left space for the RailCom cutout during data transfer 2 IdNotify The central unit sends regularly it s identificat...

Страница 39: ...cklight 8 Possible actions Adjust the LCD backlight by turning the speed control knob Possible values 0 to 16 Confirm input by pressing ok You ll then be taken back to the main menu Cancel with esc Yo...

Страница 40: ...English MasterControl Page 6 22...

Страница 41: ...ave additional power buffers which can support a locomotive when power is cut Before operating such a decoder please check how much energy is stored and which of the locomotives is able to move withou...

Страница 42: ...driving directions is sent and thus no such information is displayed Enter address ADR 216 0 Cancel ok Please enter the locomotive or function decoder s address using the keypad When entering the fir...

Страница 43: ...ion the current speed level is set to 0 which causes some decoders to execute an emergency stop With the DC mode set for the speed controller the driving direction is set by the rotating direction of...

Страница 44: ...n and off with the button function afterwards This method allows you to switch the functions f1 to f12 Displaying functions switched on When pressing shift for the last called locomotive whose data is...

Страница 45: ...and confirm by pressing ok To cancel an input press esc 216 DCC 0 3 Both addresses will be displayed on top and on the bottom of the display Both locomotives now respond simultaneously to driving comm...

Страница 46: ...itching decoder out put off Switching time The signal to switch points or a switching decoder is sent as long as you press the functions key Nonetheless the minimum and maximum switching time is limit...

Страница 47: ...ok The locomotive is then locked and the lock sign is displayed Entering the address again or entering another turns the lock off Specialities of a double traction A double traction stays under contr...

Страница 48: ...English MasterControl Page 7 8...

Страница 49: ...pdate application Please note Always connect the MasterControl to your PC before executing the update application Otherwise your PC might have difficulties detecting the interface Follow the instructi...

Страница 50: ...English MasterControl Page 8 2...

Страница 51: ...epeat your input and if necessary enter additional blanks When switching on the MasterControl it blocks when displaying its version number Possible reason The locomotive database contains corrupted da...

Страница 52: ...e causing problems They do not respond to driving or function commands or have an odd driving behaviour Possible reason The duration of the signal pause is set inaccurately Change the duration of the...

Страница 53: ...ooster s88 feedback module RS232 PC USB PC EasyNet e g for LokControl Maximum amount of s88 modules 32 s88 or s88 compatible modules Maximum amount of locomotive addresses 255 in the Motorola format 1...

Страница 54: ...36 EWG on electromagnetic radiation and is therefore CE certified Guarantee Conditions This product carries a two year garantee covering material defect and fabrication errors We also guarantee the ad...

Страница 55: ...mation about the status of the four functions and the absolute driving direction The Motorola II format allows only 14 speed levels as well In the meantime decoders have become available which support...

Страница 56: ...mming allows you to set a decoders properties by setting the so called configuration variables CV variables The meaning of each variable is clearly defined by the NMRA Each variable has 8 bits and can...

Страница 57: ...s is facilitated by switching on off the power The interval between those power peeks is called PMW period By altering the PMW period the individual running characteristics of an electric motor are ch...

Страница 58: ...r consumption a locomotive Gauge N 600 mA Gauge H0 800 mA Gauge 0 1 A a wagon light 50 200 mA another consumer such as a sound module 100 300 mA reserve for points 10 of the calculated sum of power co...

Отзывы: