Configura tion variables fo r the DCC format (exert)
CV#
CV name
Value
(Default value)
Explanations
1
Primary address
0 ... 127
(3)
The primary address contains a value between 1
and 127. Is the CV#1 equal to 0, the decoder
switches to analog mode.
2
Vstart
0 ... 255
(-)
Defines the current powering the engi ne at
minimum speed.
3
Acceleration rate
0 ... 255
(-)
Defines the duration of the pause while
switching up to the next higher speed level.
4
Deceleration rate
0 ... 255
(-)
Defines the duration of the pause while
switching down to the next lower speed level.
5
Vhigh
0 ... 255
(0)
Defines the current powering the engi ne at
maximum speed.
6
Vmid
1 ... 255
(1)
Defines the current powering the engi ne at
moderate speed.
7
Manufacturer
version No.
1 ... 255
This is the version number of the decoder’s
internal software.
8
Manufacturer ID
e.g. 62
In this case: Tams Elektronik GmbH
9
Total PWM period
0 ... 255
(0)
The current powering the electric motors is
facilitated by switching on / off the power. The
interval between those power peeks is called
PMW period. By altering the PMW period, the
individual running characteristics of an electric
motor are changed.
17 + 18 Extended address
1 ... 10239
(-)
Defines the address between 1 and 10239, if the
decoder is set to extended addresses.
19
Consist address
0 ... 127
(-)
Defines the alternate (second) address of the
decoder .
29
Configuration data
#1
0 ... 255
(-)
Defines main properties of the decoder:
Driving direction, amount of speed steps,
switching to analog operation, additional
feedback while in programming mode, choice
of the speed table, primary addresses or
extended addresses.
33 – 46
Output Loc. FL(f),
FL(r), F1-F12
0 ... 255
(-)
Contains a matrix indication of which function
inputs control which Digital Decoder outputs.
49 – 64
Manufacturer
Unique
0 ... 255
(-)
Reserved for manufacturer unique CV’s.
67 – 94
Speed Table
(only in 28 speed
steps mode)
0 ... 255
(-)
A speed table consisting of 28 values for
forward speeds forming a smooth power
curve, whereas each speed step is assigned a
specific engine power value.
A value of “0” is defined as no power, a value
of “255” as maximum power.
Содержание MasterControl 40-01007
Страница 4: ...English MasterControl Page 0 2...
Страница 8: ...English MasterControl Page 1 4...
Страница 14: ...English MasterControl Page 4 2...
Страница 18: ...English MasterControl Page 5 4...
Страница 40: ...English MasterControl Page 6 22...
Страница 48: ...English MasterControl Page 7 8...
Страница 50: ...English MasterControl Page 8 2...