Controlling with External Analog & Contact Signals
139
Toggling Output ON/OFF with Isolated External Contacts
* This function can be set for isolation-option-featured type "model name with I" only.
The output for HX-S-G2 Series power supplies can be toggled ON/OFF using outputs from small capacity contact
or photocoupler.
Use a photocoupler or a small signal relay or switch with a minimum contact capacity of 5V, 2.5mA.
FUNCTION settings must be changed to "Valid" for Output ON/OFF Control at External Contact Points to be used.
Factory default settings are set to "Invalid".
Connecting
Wire the cables to the isolated control connector (accessory) terminals No. 8 and 10.
Insulation Control Connector
Photocoupler or Contact
8
Twisted-Pair Wire
10
Open: Output OFF
Closed: Output ON
Toggling Output ON/OFF with Insulation External Contacts
Not suited for power contacts such as main
contacts for electromagnetic contactors or power
relays, etc.
!
CAUTION
Содержание HX-S-01000-12G2
Страница 165: ...Special Loads 165 This page is blank...
Страница 169: ...Maintenance 169 This page is blank...
Страница 211: ...Specifications 211 External Diagrams 1 HX S 030 200G2 F I...
Страница 212: ...Specifications 212 2 HX S 030 400G2 F I...
Страница 213: ...Specifications 213 3 HX S 060 100G2 F I...
Страница 214: ...Specifications 214 4 HX S 060 200G2 F I...
Страница 215: ...Specifications 215 5 HX S 0120 50G2 F I...
Страница 216: ...Specifications 216 6 HX S 0120 100G2 F I...
Страница 217: ...Specifications 217 7 HX S 0400 15G2 F I...
Страница 218: ...Specifications 218 8 HX S 0400 30G2 F I...
Страница 219: ...Specifications 219 9 HX S 0500 12G2 F I...
Страница 220: ...Specifications 220 10 HX S 0500 24G2 F I...
Страница 221: ...Specifications 221 11 HX S 01000 6G2 F I...
Страница 222: ...Specifications 222 12 HX S 01000 12G2 F I...
Страница 223: ...Specifications 223...
Страница 239: ......