Basic Usage
34
Function Settings Items List
General Functions
Item
No.
Settings Item
Range and contents of Parameter
Default Value
0
Gen
eral F
un
cti
on
s
Firmware Version
Ex: 1.00 (Cannot be changed)
1
Startup Mode Selection
0=CV Priority (High Speed)
2=CV Priority (Low Speed)
* This function can be set for full-
featured type
"model name with F" only
1=CV Priority (Medium Speed)
2=CV Priority (Low Speed)
3=CV Slew Rate
4=CC Priority (High Speed)
5=CC Priority (Medium Speed)
6=CC Priority (Low Speed)
7=CC Slew Rate
2
CV Slew Rate Rising
30V Type
:
0.01V/S-60.00V/S
60V Type
:
0.1V/S-120.0V/S
120V Type:0.1V/S-240.0V/S
400V Type:0.1V/S-800.0V/S
500V Type
:
1V/S-1000V/S
1000V Type
:
1V/S-2000V/S
Maximum of parameter range
* This function can be set for full-
featured type
"model name with F" only
3
CV Slew Rate Falling
4
CC Slew Rate Rising
HX-S-030-200
:
0.1A/S-400.0A/S
HX-S-030-400
:
0.1A/S-800.0A/S
HX-S-060-100
:
0.1A/S-200.0A/S
HX-S-060-200
:
0.1A/S-400.0A/S
HX-S-0120-50:
0.01A/S-100.0A/S
HX-S-0120-100
:
0.01A/S-200.0A/S
HX-S-0400-15
:
0.01A/S-30.00A/S
HX-S-0400-30
:
0.01A/S-60.00A/S
HX-S-0500-12
:
0.01A/S-24.00A/S
HX-S-0500-24
:
0.01A/S-48.00A/S
HX-S-01000-6
:
0.01A/S-12.00A/S
HX-S-01000-12
:
0.01A/S-24.00A/S
Maximum of parameter range
When Parallel Connection:
(Maximum Output Current x 2)/s
* This function can be set for full-
featured type
"model name with F" only
5
CC Slew Rate Falling
6
Serial I/F2
0=Serial Data Communication
Control (Remote Mode)
0=Serial Data Communication
Control (Remote Mode)
* This function can be set for
full-featured type
"model name with F" only
1=Use for Sequential ON/OFF
(Local Mode)
7
ON Delay Time
0.00s~99.99s
0.00s
* This function can be set for full-
featured type
"model name with F" only
8
OFF Delay Time
0.00s~99.99s
9
Operation during Alarm
0= Stop switching
0= Stop switching
1=Input Switch TRIP
(Only for TRIP input and serious
failures)
2=Input Switch TRIP
(TRIP input, serious failures, OVP,
and OCP)
10
Output ON/OFF Toggle with
External Contact
0=Invalid
0=Invalid
1=When close Output is ON, When
open Output is OFF
2=When close can be ON/OFF by
panel control, When open Output
is OFF
11
Measurement
Value
Moving
Average Processing
0=No
0=No
1=Yes
12
Linearity Compensation Function
Operation Mode
0=Compensation Mode OFF
1=Operates when Output is
turned ON/OFF or when settings
are changed.
Saves compensation value after
converging
1=Operates when Output is turned
ON/OFF or when settings are
changed.
Saves compensation value after
converging
2=Performs continuous
compensation
Содержание HX-S-01000-12G2
Страница 165: ...Special Loads 165 This page is blank...
Страница 169: ...Maintenance 169 This page is blank...
Страница 211: ...Specifications 211 External Diagrams 1 HX S 030 200G2 F I...
Страница 212: ...Specifications 212 2 HX S 030 400G2 F I...
Страница 213: ...Specifications 213 3 HX S 060 100G2 F I...
Страница 214: ...Specifications 214 4 HX S 060 200G2 F I...
Страница 215: ...Specifications 215 5 HX S 0120 50G2 F I...
Страница 216: ...Specifications 216 6 HX S 0120 100G2 F I...
Страница 217: ...Specifications 217 7 HX S 0400 15G2 F I...
Страница 218: ...Specifications 218 8 HX S 0400 30G2 F I...
Страница 219: ...Specifications 219 9 HX S 0500 12G2 F I...
Страница 220: ...Specifications 220 10 HX S 0500 24G2 F I...
Страница 221: ...Specifications 221 11 HX S 01000 6G2 F I...
Страница 222: ...Specifications 222 12 HX S 01000 12G2 F I...
Страница 223: ...Specifications 223...
Страница 239: ......