Basic Usage
36
Settings Items List (Continued)
Communication Functions, External Control
Item
No.
Settings Item
Range and contents of Parameter
Default Value
52
Pa
nel O
pe
rati
o
n
Voltmeter/Ammeter
Display
when OUTPUT is OFF
0=Displays Measurement Values
0=Displays Measurement
Values
1=Displays Set Values
53
LOCK Mode Selection
0 = only LOCK key is valid
0 = only LOCK key is valid
1 = only OUTPUT and LOCK keys
are valid
2 = VOLTAGE/CURRENT dial,
PRESET, FUNC., OVP, and
OCP are invalid
54
Panel Memory Key Load
Procedure
0=Single-Action
1=Double-Action
1=Double-Action
60
Co
mmunicati
o
n Fun
ctio
ns
Device Address
1 to 50
1
61
Bitrate
0=2400bps
1=9600bps
1=9600bps
2=19200bps
3=38400bps
62
Parity
0=No
0=No
1=ODD
2=EVEN
63
Command Form
0 = SCPI Standard Conformance
0 = SCPI Standard
Conformance
1 = HX Series Compatible
70
Extern
al
C
on
tr
ol
CV Control
EXT R/V, PANEL Settings
0=Front Panel
0=Front Panel
*Function of 2 to 4,It is
impossible to use HX-S-
01000-G2
1=External Voltage(0~10V)
2=External Resistance(0~10kΩ A)
3=External Resistance(0~10kΩ B)
4=External Resistance(0~10kΩ C)
71
CC Control
EXT R/V, PANEL Settings
0=Front Panel
0=Front Panel
*Function of 2 to 4,It is
impossible to use HX-S-
01000-G2
1=External Voltage(0~10V)
2=External Resistance(0~10kΩ A)
3=External Resistance(0~10kΩ B)
4=External Resistance(0~10kΩ C)
72
Internal Resistance Settings
HX-S-030-200
:
0Ω-0.15Ω
HX-S-030-400
:
0Ω-0.075Ω
HX-S-060-100
:
0Ω-0.6Ω
HX-S-060-200
:
0Ω-0.3Ω
HX-S-0120-50
:
0Ω-0.24Ω
HX-S-0120-100: 0Ω-0.12Ω
HX-S-0400-15
:
0Ω-26.7Ω
HX-S-0400-30
:
0Ω-13.3Ω
HX-S-0500-12
:
0.Ω-41.7Ω
HX-S-0500-24
:
0Ω-20.8Ω
HX-S-01000-6
:
0Ω-167Ω
HX-S-01000-12
:
0Ω-83Ω
0Ω
* This function can be set for
full-featured type "model
name with F" only
73
Series Operation
0=Master
0=Master
*This function is impossible to use
HX-S-01000-G2
1=Slave
74
LEVEL1_ALM
CV_STS
0=Is not included in LEVEL1_ALM
0=Is not included in
LEVEL1_ALM
1=Included in LEVEL1_ALM
75
CC_STS
0=Is not included in LEVEL1_ALM
0=Is not included in
LEVEL1_ALM
1=Included in LEVEL1_ALM
76
LEVEL1_ALM/
OUTPUT ON/OFF_STS Selection
0
=
LEVEL1_ALM
0
=
LEVEL1_ALM
1
=
OUTPUT ON/OFF_STS
Содержание HX-S-01000-12G2
Страница 165: ...Special Loads 165 This page is blank...
Страница 169: ...Maintenance 169 This page is blank...
Страница 211: ...Specifications 211 External Diagrams 1 HX S 030 200G2 F I...
Страница 212: ...Specifications 212 2 HX S 030 400G2 F I...
Страница 213: ...Specifications 213 3 HX S 060 100G2 F I...
Страница 214: ...Specifications 214 4 HX S 060 200G2 F I...
Страница 215: ...Specifications 215 5 HX S 0120 50G2 F I...
Страница 216: ...Specifications 216 6 HX S 0120 100G2 F I...
Страница 217: ...Specifications 217 7 HX S 0400 15G2 F I...
Страница 218: ...Specifications 218 8 HX S 0400 30G2 F I...
Страница 219: ...Specifications 219 9 HX S 0500 12G2 F I...
Страница 220: ...Specifications 220 10 HX S 0500 24G2 F I...
Страница 221: ...Specifications 221 11 HX S 01000 6G2 F I...
Страница 222: ...Specifications 222 12 HX S 01000 12G2 F I...
Страница 223: ...Specifications 223...
Страница 239: ......