78
3.4.4 Operation
Before a meeting starts, the HCS-8336 SDI monitor
need to be configured by the operator, including:
numbering and testing. During the meeting, the
interpreters use the SDI monitor to switch videos, call
service, etc.
1. Number
First of all, make sure that the HCS-8336 SDI monitors
are connected properly to the CMU. All SDI monitors
must be numbered when the system is used for the first
time or when adding or replacing SDI monitors. The
numbering function can be activated by menu
operation on the CMU front panel or by application
software.
Select “Number” by menu operation from the CMU,
press the “MENU” key to confirm. The system now
goes to numbering status.
“Press ‘1’ key of all congress
units one by one and repower”
will be displayed on the
CMU LCD. The number indicating light of all connected
SDI monitors will blink. All SDI monitors will display
“Numbering”
. Press key “
-
” of every SDI monitor one by
one. The number indicating light will be deactivated.
Once all SDI monitors numbered, restart the CMU to
update the number information.
2. Video Switch
Select video input signal, and the signal name can be
edited by TAIDEN conference management software.
Press the “Source” button to select input signal
circularly.
3. Service
Supports service function, and the service type name
can be edited by TAIDEN conference management
software. Press the “
+
” key or the “
-
” key to select
service and then press the “Menu” key to confirm.
7. OSD menu
After initialization, touch the key “Menu” / “+” / “-” on the
right of the front panel to active the OSD menu. The
OSD menu will be hidden automatically if no operation
for 5 seconds.
Menu key: confirm (
)
+ key: move up ( )
- key: move down ( )
A. “System Setting”
System setting includes Brightness, Standby,
Language and Aspect video. Select a sub-menu, the
item will be highlight with blue; when pressing the
“Menu” key, the item will be highlight with red. It means
that the content of this item can be modified by
pressing “+” key or “-” key and then press the “Menu”
key again to confirm.
Note:
The SDI monitor was numbered together
with congress units in the venue, the IDs of
SDI monitors cannot be the same with
congress units;
When numbering, please number the SDI
monitors one by one and do NOT press the
“NUMBER” key of several SDI monitors at
the same time.
Содержание hcs-8300
Страница 22: ...9 Figure 1 1 6 CongressMatrix TM Software Interface ...
Страница 25: ...12 Figure 1 1 10 By using microphone array terminals the conference room looks tidy ...
Страница 89: ...76 3 4 2 Installation Figure 3 4 2 Fixing of HCS 8336 SDI monitor ...
Страница 93: ...80 B About Display the product information including unit ID serial and version ...
Страница 121: ...108 4 1 HCS 4385U 50 4 1 1 Functions and indications Front Side Bottom Figure 4 1 1 HCS 4385U 50 Interpreter unit ...
Страница 134: ...121 4 2 HCS 8385 4 2 1 Functions and indications Front Side Bottom Figure 4 2 1 HCS 8385 Interpreter unit ...
Страница 168: ...155 Figure 6 1 3 CMU connecting to infrared language distribution system via HCS 8300MO ...
Страница 210: ...197 6 9 2 Connection Figure 6 9 4 Connection between the HCS 8301M and the HCS 8300MAU FS ...
Страница 249: ...236 Appendices Custom made cables AppendixⅠ Dedicated 6 PIN Extension Cable ...
Страница 250: ...237 Appendix Ⅱ CBL2SS 01 Professional 2 pin Cable for Conference System ...
Страница 251: ...238 Appendix Ⅲ CBL4PK 01 Power Adapter Cable ...
Страница 252: ...239 Appendix Ⅳ CBL4PT 02 Power Branch Cable ...
Страница 253: ...240 Appendix Ⅴ CBL4PS 4 pin Extension Cable ...
Страница 254: ...241 Appendix Ⅵ Cat 6 Gigabit Ethernet Cable ...