1A-101 Engine General Information and Diagnosis:
5
1) If the EXCVA position sensor output voltage is 0.5 V and
less at EXCV fully closed position, adjust the output
voltage to the specified value by adjusting the length of
EXCV cable No. 1. Refer to “EXCVA / EXCV Cable
Removal and Installation in Section 1K (Page 1K-4)”.
2) Repeat the procedure in Step 4 until the output voltage is
set within the specified value. (If C46/P1657 code is
indicated after adjusting the voltage, increase the
voltage to 0.4 V).
CAUTION
!
• Adjusting the cable with the EXCV fully
opened or fully closed can damage the
EXCVA. Be sure to adjust the cable with the
EXCV set in the adjustment position. Refer to
“EXCVA / EXCV Cable Removal and
Installation in Section 1K (Page 1K-4)”.
• Do not turn the EXCVA pulley using the
wrench.
3) If the EXCVA position sensor output voltage is 4.55 V
and more at EXCV fully opened position, adjust the
output voltage to the specified value by adjusting the
EXCV cable No. 2. Refer to “EXCVA / EXCV Cable
Removal and Installation in Section 1K (Page 1K-4)”.
Repeat the procedure in Step 4 until the output voltage is
set within the specified value.
EXCVA position sensor output voltage
EXCV is fully closed: 0.5
≤
Output voltage
≤
1.5
EXCV is fully opened: 3.5
≤
Output voltage
≤
4.5
Is the voltage OK?
Replace the ECM with a
known good one, and
inspect it again.
Replace the EXCVA
with a new one.
Step
Action
Yes
No
Содержание VLR1800
Страница 4: ......
Страница 64: ...0C 12 Service Data...
Страница 456: ...2D 22 Wheels and Tires...
Страница 489: ...Drive Chain Drive Train Drive Shaft 3A 31 09951 17010 Bearing installer Page 3A 19...
Страница 490: ...3A 32 Drive Chain Drive Train Drive Shaft...
Страница 580: ...6B 11 Steering Handlebar...
Страница 623: ...Prepared by January 2008 Part No 99500 39360 01E Printed in Japan 624...