Functional Parameter Table
V260 Series High Performance Closed-Loop Vector Inverter User Manual
52
Function
Code
Name
Setting Range and Description
Minimum
Unit
Factory
Default
Chang
e Limit
F2.1.32 Stator
resistance
0.01~65000m
Ω
☆
☆
×
F2.1.33 Stator
inductance
0.001~6500.0mH
☆
☆
×
F2.1.34
Total leakage
inductance
0.001~6500.0mH
☆
☆
×
F2.1.35
Rotator time constant
5.0~6500.0ms
0.1ms
☆
×
F2.1.36
Slip compensation
coefficient
0.25~2.00 0.01
1.00
F2.1.37
~F2.1.49
Retention parameter
×
F2.1.50
Z pulse initial angle
0.0~359.9
0.1
0.0
×
F2.1.51
Motor overload
protection coefficient
50.0~131.0(%) (131—closed)
0.1
110.0
6.2.13 PARAMETER MEASUREMENT AND PRE-EXCITATION
Function
Code
Name
Setting Range and Description
Minimum
Unit
Factory
Default
Change
Limit
F2.2.52
Start excitation time in
vector mode
0.02~2.50Sec. 0.01
☆
F2.2.53
Motor parameter
measurement
0: Closed
1: Static identification
2: operating parameter
identification
3: operating parameter
identifi revolution ratio
identification
1 0 ×
6.2.14 MULTIFUNCTIONAL INPUT TERMINAL
Function
Code
Name
Setting Range and Description
Minimum
Unit
Factory
Default
Change
Limit
F3.0.00
Multifunctional input
terminal DI1
0~96 1
0
×
F3.0.01
Multifunctional input
terminal DI2
0~96 1
0
×
F3.0.02
Multifunctional input
terminal DI3
0~96 1
7
×
F3.0.03
Multifunctional input
terminal DI4
0~96 1
8
×
F3.0.04
Multifunctional input
terminal DI5
0~96 1
13
×
F3.0.05
Multifunctional input
terminal DI6
0~96 1
0
×
¾
The stator resistance, stator inductance and the Minimum Unit of total leakage inductance
of asynchronous motors is relevant with different models.