108 Description Of Specific Functions
V260 Series High Performance Closed-Loop Vector Inverter User Manual
11:
√
(Channel 1) +
√
(Channel 2)
Frequency set value =
√
|set value 1|+sqrt|set value 2|
The frequency set value is the total of the square root of the absolute value of set value 1 and set value 2,
and the combination value must be unipolar.
12:
√
(Channel 1 + Channel 2)
Frequency set value =
√
|set value 1+set value 2|
The frequency set value is square root of the absolute value of the total of set value 1 and set value 2, and
the combination value must be unipolar.
13: (Channel1 x Scaling 1) + (Channel 2 x Scaling 2)
Frequency set value=set value 1*[F0.1.18]+set value 2*[F0.1.19]
Only when the two setting channels are both in the mode of bipolar setting, the combination results will show
the characteristics of the bipolar setting.
14: (Channel1 x Scaling 1) + (Channel 2 x Scaling 2)
Set value 1*[F0.1.18]- set value 2*[F0.1.19]
Only when the two setting channels are both in the mode of bipolar setting, the combination results will show
the characteristics of the bipolar setting.
Remarks: after selecting the combination way of the frequency set value, the following aspects must
be considered in order to get correct frequency set value
To
set
F0.2.25
(channel selection for the frequency setting source 1) and
F0.2.26
(channel selection for
the frequency setting source 2) to determine the given channel of the frequency setting source;
To
set
F0.1.18
(action coefficient of the frequency setting source 1) and
F0.1.19
(action coefficient of the
frequency setting source 2) to determine the weighting coefficient of the frequency setting source;
To
Set
F0.2.27
(minimum set value of frequency source 1) and
F0.2.28
(maximum set value of frequency
source 1) to limit the range of frequency set value of the frequency source 1, and to set F0.2.30
(minimum set value of frequency source 2) and
F0.2.31
(maximum set value of frequency source 2) to
limit the range of frequency set value of the frequency source 2;
To
set
F0.1.21
(upper limiting frequency) and
F0.1.22
(lower limiting frequency) to limit the range of the
frequency set value.
F0.1.17 Running direction (H)
Setting range: 0000~0021
Factory default: 0000
_ _ _ X : Direction switching
0: Void
The running direction is controlled by the direction command.
1: Negate
The running direction is opposite to that directed by the direction command.
_ _ X _ : Direction locking
0: Void
The running direction is controlled by the direction command.
1: FWD locking
The motor will run in FWD direction No matter the FWD running command or REV running command is
given.