background image

Please

Recycle

Copyright © 2008 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved.

Sun Microsystems, Inc. has intellectual property rights relating to technology embodied in the product that is described in this document. In

particular, and without limitation, these intellectual property rights may include one or more of the U.S. patents listed at

http://www.sun.com/patents and one or more additional patents or pending patent applications in the U.S. and in other countries.

This distribution may include materials developed by third parties.

Parts of the product may be derived from Berkeley BSD systems, licensed from the University of California. UNIX is a registered trademark in

the U.S. and in other countries, exclusively licensed through X/Open Company, Ltd.

Sun, Sun Microsystems, the Sun logo, Java, Netra, Solaris, Sun Ray, Sun Blade, docs.sun.com, SunVTS, OpenBoot, JumpStart and the Solaris

logo are trademarks or registered trademarks of Sun Microsystems, Inc. in the U.S. and other countries.

Microsoft is a trademark or registered trademark of Microsoft Corporation or its subsidiaries in the United States and Other countries. Windows

is a trademark or registered trademark of Microsoft Corporation or its subsidiaries in the United States and Other countries. The Adobe logo is a

registered trademark of Adobe Systems, Incorporated.

Use of any spare or replacement CPUs is limited to repair or one-for-one replacement of CPUs in products exported in compliance with U.S.

export laws. Use of CPUs as product upgrades unless authorized by the U.S. Government is strictly prohibited.

DOCUMENTATION IS PROVIDED "AS IS" AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES,
INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT,
ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID.

Copyright © 2008 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, Etats-Unis. Tous droits réservés.

Sun Microsystems, Inc. détient les droits de propriété intellectuels relatifs à la technologie incorporée dans le produit qui est décrit dans ce

document. En particulier, et ce sans limitation, ces droits de propriété intellectuelle peuvent inclure un ou plus des brevets américains listés à

l’adresse http://www.sun.com/patents et un ou les brevets supplémentaires ou les applications de brevet en attente aux Etats - Unis et dans les

autres pays.

Cette distribution peut comprendre des composants développés par des tierces parties.

Des parties de ce produit pourront être dérivées des systèmes Berkeley BSD licenciés par l’Université de Californie. UNIX est une marque

déposée aux Etats-Unis et dans d’autres pays et licenciée exclusivement par X/Open Company, Ltd.

Sun, Sun Microsystems, le logo Sun, Java, Netra, Solaris, Sun Ray, Sun Blade, docs.sun.com, SunVTS, OpenBoot, JumpStart et le logo Solaris

sont des marques de fabrique ou des marques déposées de Sun Microsystems, Inc. aux Etats-Unis et dans d’autres pays.

Microsoft sont est marques de fabrique ou des marques déposées de Microsoft Corporation ou de sa filiale aux Etats-Unis et dans d’autres pays.

Windows est une marque de fabrique ou une marques déposée de Microsoft Corporation ou de sa filiale aux Etats-Unis et dans d’autres pays.

Le logo Adobe est une marque déposée de Adobe Systems, Incorporated.

L’utilisation de pieces detachees ou d’unites centrales de remplacement est limitee aux reparations ou a l’echange standard d’unites centrales

pour les produits exportes, conformement a la legislation americaine en matiere d’exportation. Sauf autorisation par les autorites des Etats-

Unis, l’utilisation d’unites centrales pour proceder a des mises a jour de produits est rigoureusement interdite.

LA DOCUMENTATION EST FOURNIE "EN L’ETAT" ET TOUTES AUTRES CONDITIONS, DECLARATIONS ET GARANTIES EXPRESSES
OU TACITES SONT FORMELLEMENT EXCLUES, DANS LA MESURE AUTORISEE PAR LA LOI APPLICABLE, Y COMPRIS NOTAMMENT
TOUTE GARANTIE IMPLICITE RELATIVE A LA QUALITE MARCHANDE, A L’APTITUDE A UNE UTILISATION PARTICULIERE OU A
L’ABSENCE DE CONTREFACON.

Содержание Blade X8400

Страница 1: ...Sun Microsystems Inc www sun com Submit comments about this document at http www sun com hwdocs feedback Sun Blade X8400 Server Module Installation Guide Part No 820 3619 11 March 2008 Revision A...

Страница 2: ...etwork Circle Santa Clara California 95054 Etats Unis Tous droits r serv s Sun Microsystems Inc d tient les droits de propri t intellectuels relatifs la technologie incorpor e dans le produit qui est...

Страница 3: ...Operating Systems 5 Managing the Sun Blade Server Module With ILOM 6 Service Processor 6 Chassis Monitoring Module 6 ILOM on the Server Module SP and CMM 7 2 Server Module Installation and Power On 9...

Страница 4: ...odule 25 Attach Local Serial Console to the Server Module 25 Attach Local VGA Monitor to the Server Module 26 Attach USB Devices to the Server Module 27 What to Do Next 28 3 Establish Communication Wi...

Страница 5: ...sed in these documents Sun Blade 8000 Series Product Notes Sun Blade 8000 Series Installation Guide Sun Blade 8000 Series Online Information System Sun Integrated Lights Out Manager 2 0 User s Guide R...

Страница 6: ...ngs Meaning Examples AaBbCc123 The names of commands files and directories on screen computer output Edit your login file Use ls a to list all files You have mail AaBbCc123 What you type when contrast...

Страница 7: ...documentation part number identifies the latest version of the product documentation that is available for download or viewing online For example 819 xxxx XX Additional Sun documentation is available...

Страница 8: ...vides information about Supported operating systems Identification of system drivers installed by SIA Using SIA to install operating systems on a Sun Blade 8000 Series Server Module 820 3357 PDF Onlin...

Страница 9: ...stions You can submit your comments by going to http www sun com hwdocs feedback Please include the following title and part number of your document with your feedback Sun Blade X8400 Server Module In...

Страница 10: ...x Sun Blade X8400 Server Module Installation Guide March 2008...

Страница 11: ...with the hardware and software features of the Sun Blade X8400 Server Module This chapter contains the following topics Hardware Overview on page 2 Environmental Requirements on page 3 Server Module...

Страница 12: ...GB DDR DIMMs Hard Disk Drive Support for up to two drives per blade X8400 Medium Configuration CPU 4x Opteron 875 2 2 GHz dual core 64 bit Memory 16 GB 8x2GB DDR DIMMs Hard Disk Drive Support for up t...

Страница 13: ...ress Modules NEMs or PCIe ExpressModules EMs Indicators and Buttons The Sun Blade server module includes standard service indicator LEDs and buttons For more information see Server Module Indicators a...

Страница 14: ...rver Module Indicators and Buttons Figure Legend 1 VGA video port 2 USB ports 2 3 Serial port 4 Disk Drive Ready to Remove LED 5 Disk Drive Service Action Required LED 6 Disk Drive OK Activity LED 7 S...

Страница 15: ...soft Windows Server 2008 Enterprise Edition 32 bit and 64 bit VMware ESX Server or later Factory Installed Operating Systems For your convenience you can order the hard disk drives for the Sun Blade s...

Страница 16: ...e Processor The service processor SP is the ILOM firmware It has its own Internet Protocol IP address and media access control MAC address and is capable of operating regardless of the state of the ot...

Страница 17: ...sing the Server Module SP Managing the SP on a Sun Blade server module enables you to manage operations on an individual server module This approach might be useful when troubleshooting a specific ser...

Страница 18: ...8 Sun Blade X8400 Server Module Installation Guide March 2008...

Страница 19: ...ains the following topics System Chassis Prerequisites on page 10 Handling the Server Module on page 10 Add Memory Modules to the Server Module on page 11 Add Hard Disk Drives to the Server Module on...

Страница 20: ...of the Sun Blade 8000 Series Installation Guide are posted to the Sun documentation site To ensure you locate the latest version of this guide search for the title or part number 819 5647 of the guid...

Страница 21: ...parately About Memory Modules The X8400 Server Module uses 2 5V error correcting ECC high capacity dual inline memory modules DIMMs The DIMMs are built with double data rate synchronous dynamic access...

Страница 22: ...ight of the server module 2 Remove the server module cover by performing the following steps a Place the server module on a stable antistatic work surface For example place the server module on top of...

Страница 23: ...npack the new from its antistatic container 5 Ensure that the DIMM ejector levers are open angled outward then align the DIMM notch to the DIMM connector key 6 Using both thumbs press the DIMM straigh...

Страница 24: ...that the DIMM ejector levers are upright seated and tight Press on the ejector levers to ensure that they are engaged properly 8 To install the second DIMM repeat Steps 4 through 7 9 To reinstall the...

Страница 25: ...beled HDD0 1 located on the front panel of the server module see figure below Note Installation of a hard disk drive is not necessary if you are configuring the server module to boot from an FC SAN de...

Страница 26: ...you are not installing a hard disk drive do not remove the HDD filler panel from the server module The HDD filler panels are required to meet FCC standards for EMI Caution The following HDD procedure...

Страница 27: ...er module locate the HDD filler panel that you want to remove Note that the HDD filler panel ejector lever is in the closed position 3 Push the HDD ejector lever button to unlatch the lever then tilt...

Страница 28: ...slot on the server module Note If you are installing a single configuration HDD that has a factory installed version of the Solaris 10 Operating System you must install that factory installed Solaris...

Страница 29: ...pect to the faceplate when sliding in the HDD into the slot Do not slide the HDD in all the way Leave the HDD out approximately 0 25 to 0 50 inch from the opening 8 Using your thumb or finger press on...

Страница 30: ...ou are not installing a server module into a slot do not remove the server module filler panel from the slot The server module filler panel is required to meet FCC standards for EMI Use the following...

Страница 31: ...ttom then pivot out and raise the top ejector lever and lower the bottom ejector lever 3 Hold the ejector levers and pull the filler panel out of the chassis slot Install Server Module Into Chassis Sl...

Страница 32: ...le power on out of box When a server module powers on for the first time in a Sun Blade system chassis it automatically receives standby power This power state indicates that the server module SP is a...

Страница 33: ...On in the Sun Blade 8000 Series Installation Guide for more information 2 Determine whether the Sun Blade server module is receiving standby power or main power Server Module SP Standby Power The OK p...

Страница 34: ...above the Power button displays a solid green light Troubleshooting the Server Module Power On State If the server module is not receiving power consider the following The server module SP power poli...

Страница 35: ...module Attach Local Devices to Server Module Each server module provides one VGA port two USB ports and one serial port These local server module ports enable direct communication with the server modu...

Страница 36: ...odule Prerequisite The VGA resolution is fixed to 1024x768x60 Hz Ensure that your VGA monitor supports this resolution prior to connecting Follow these steps to attach a local VGA monitor to a Sun Bla...

Страница 37: ...attach any of the following local USB devices to a Sun Blade server module External media drives CD DVD and Floppy Mouse or other pointing device Keyboard Follow these steps to attach local USB devic...

Страница 38: ...nstalling the blade into the chassis and applying power to the blade you should proceed to the next section that describes how to configure an IP address for the server module SP and how to establish...

Страница 39: ...e information about how to attach the CMM management network cable see Attach CMM Management Network Cable in Chapter 4 of the Sun Blade 8000 Series Installation Guide 819 5647 The type of connection...

Страница 40: ...tial IP address If you are not utilizing a DHCP server to assign IP addresses to the server SP or CMM you must establish a local serial console connection to ILOM via the serial management port on the...

Страница 41: ...the web interface For more information about ILOM interfaces consult the Sun Blade 8000 Series Online Information System ILOM Preconfigured Admin Account Mandatory first time use Any user with a vali...

Страница 42: ...n page 25 or see Attach Serial Console to Chassis Monitoring Module in the Sun Blade 8000 Series Installation Guide Configured the following serial settings 8N1 eight data bits no parity one stop bit...

Страница 43: ...information about editing IP address settings see Edit Existing IP Addresses in ILOM Using the Web Interface on page 37 or Edit Existing IP Address es in ILOM Using the CLI on page 38 3 The DHCP serve...

Страница 44: ...default password changeme then press Enter To view the server module SP IP address type show SP network DHCP server logs For more information consult the DHCP server documentation Assign a Static IP...

Страница 45: ...and password then press Enter Note You can log in to ILOM using the preconfigured Administrator account shipped with ILOM Login root Password changeme The default prompt appears and the system is rea...

Страница 46: ...to the server SP For example typing set pendingipnetmask 255 255 255 0 would tell ILOM to assign 255 255 255 0 as the NetMask address to the server SP set pendingipgateway Type this command followed b...

Страница 47: ...rver SP or CMM in the browser address box then press Enter The ILOM Login screen appears 2 In the ILOM Login screen log in as an Administrator by entering an administrator user name and password Tip Y...

Страница 48: ...rom the remote client establish a secure connection as root to the server SP or CMM For example you can establish a secure connection from a remote SSH client to the server SP by typing the following...

Страница 49: ...ommand followed by the static NetMask address that you want to assign to the server SP or CMM For example typing set pendingipnetmask 255 255 255 0 would tell ILOM to assign 255 255 255 0 as the NetMa...

Страница 50: ...d changeme b Click Log in The ILOM web interface appears 3 In the ILOM web interface do the following To change the preconfigured Administrator password at the chassis level click the CMM in the left...

Страница 51: ...nline Information System 819 5846 What to Do Next After configuring an IP address for the Sun Blade server module and establishing a connection to the ILOM server module SP you should Install an opera...

Страница 52: ...42 Sun Blade X8400 Server Module Installation Guide March 2008...