22
Sun Blade X8400 Server Module Installation Guide • March 2008
3. Slide the server module into the vacant server module chassis slot.
As the ejectors make contact with the chassis, the bottom lever will start to rise,
and the top lever will start to lower.
4. Simultaneously close the ejector levers at the top and bottom of the server
module (lower the top ejector and raise the bottom ejector) until the levers lock
in place against the front of the server module.
Sun Blade Server Module Power-On
Policy
The server module power policy in ILOM determines the default power state of the
server module SP at boot time, for instance:
■
Initial server module power-on (out-of-box)
. When a server module powers on
for the first time in a Sun Blade system chassis it automatically receives standby
power. This power state indicates that the server module SP is active but the
server module host is powered OFF.
Note that main power to the host is required to fully operate the server. You can
apply main power to the server module (at initial setup) via the Power button on
the front panel of the server module. For more information, see
“Apply Main
Power to Server Module SP Using the Power Button” on page 24
.
■
Subsequent server module power-ons
. By default, the blade SP power-on policy
in ILOM is set to automatically return to its previous power state. For instance:
■
If main power was the last operating power state, the server module would
automatically receive main power when inserted into a powered-on chassis.