TCV e2 User Manual
11 of 36
P/N 857414 Rev A
07/01/2020
This setting controls the minimum amount of time after an accepted tightening before another
tightening should be accepted. Any additional tightenings performed within this time after an accepted
tightening will be automatically considered a reject.
TBB (Time between batches)
Default: 0
Range: 0 to 9999 seconds
This setting controls the minimum amount of time after a batch completion before another tightening
should be accepted. Any additional tightenings performed within this time after a batch completion will
be automatically considered a reject.
Serial Number
Default: 0000000000
Range: 0000000000 to 9999999999
This setting controls the serial number of the tool. The tool serial number is reported to the network
with tightenings performed by the tool.