TCV e2 User Manual
17 of 36
P/N 857414 Rev A
07/01/2020
Keep Alive
Default: 30
Range: 0 to 3600 seconds
This setting controls how often the qualifier will send a keep alive packet to the ToolsNet server if no
other packets are being sent. When set to 0, the qualifier does not send keep alive packets. This value is
recommended to be less than half the inactivity timeout of the server to ensure the connection is not
closed due to a single missed keep alive packet. For example, if the server is configured to timeout after
30 seconds of inactivity, the keep alive setting on the unit should be less than 15 seconds.
System Number
Default: 0001
Range: 0 to 9999
This setting controls the system number the qualifier reports to the ToolsNet server in identification and
tightening packets. Each interface may be assigned its own System number.
Station Number
Default: 0001
Range: 0 to 9999
This setting controls the station number the qualifier reports to the ToolsNet server in identification and
tightening packets. Each interface may be assigned its own Station number.
Retries
Default: 2
Range: 0 to 10
This setting controls how many times the qualifier will resend a tightening or keep alive packet to the
ToolsNet server before considering the connection broken. If no response is received within the
specified result timeout, the qualifier will try again, up to the specified number of retries. If no response
is received after all retries, the ToolsNet connection is considered broken and will have to be re-
established.