Range: 0 to tool capacity
Available Modes: all
This setting controls the minimum required torque for a valid tightening. This value must be less than
Max Torque.
Target Torque
Default: 10% of tool capacity
Range: Min Trq to Max Trq
Available Modes: all
This setting controls the target torque for the tool.
Max Torque
Default: 99% of tool capacity
Range: 0 to tool capacity
Available Modes: all
This setting controls the maximum allowed torque for a valid tightening. This value must be greater than
Min Torque.
Min Angle
Default: 0
Range: 0 to 9999
Available Modes: TAM
This setting controls the minimum required angle for a valid tightening. This value must be less than Max
Ang.
Max Angle
Default: 0
Range: 0 to 9999
Available Modes: TAM
This setting controls the maximum allowed angle for a valid tightening. This value must be greater than
Min Ang.
Click Tool Fields
Timer Min
Default: 0
Range: 0 to 2.55 seconds
This setting controls the minimum amount of time the tool must be held in the clicked position for a
valid tightening. This value must be less than Timer Max.
Timer Max
Default: 1.00 seconds
Range: 0 to 2.55 seconds
This setting controls the maximum amount of time the tool may be held in the clicked position for a
valid tightening. This value must be greater than Timer Min.
TBC (Time between cycles)
Default: 0
Range: 0 to 9999 seconds