TCV e2 User Manual
21 of 36
P/N 857414 Rev A
07/01/2020
572
Name
Data Type
Description
ARRAY of
STRUCT of:
Parameter selection for each of the 2 interfaces. Each array entry
corresponds to an interface.
Item Number
SINT
Instance number of item to run on the interface. Deactivate any running
parameter or job if 0.
Reserved
SINT
Reserved in this product. Set to 0.
Batch Reset
SINT
When this value changes, the batch count of the currently running
parameter on the interface is reset.
Suspend
BOOL
When set, suspends on the interface without stopping a running
parameter or job.
Batch
SINT
Sets the batch size for the selected parameter. If this value is 0, the
parameter size stored in the TCVe2 will be used.
VIN
SINT[25]
The VIN to be used for tightenings performed on the interface
Total size: 60 bytes
Input (T->O) Connection Points
This section defines the connection points are used by TCVe2 to send output data to the network.
•
51x, 52x: Last tightening data
•
53x: Current qualifier status
Input Connection Points for Last Tightening Data
The connection points in this group will contain data about the last tightening. As such, they are not
updated after a parameter or job selection until a tightening occurs.
512
Name
Data Type
Description
ARRAY of
STRUCT of:
Last tightening data for each of the 2 interfaces. Each array entry corresponds
to an interface.
Tightening ID
DINT
ID number of the last tightening
Time
SINT[6]
Timestamp of the last tightening
Reserved
INT
Reserved in this product. Set to 0.
Reserved
SINT
Reserved in this product. Set to 0.
Parameter
SINT
Number of the parameter that produced the tightening
Tightening Status
BOOL
Indicates if the last tightening was accepted as valid.
Count
SINT
Number of results performed in the current batch for the parameter.
Batch
SINT
Number of results required for a batch in the parameter.
Total size: 34 bytes