TCV e2 User Manual
15 of 36
P/N 857414 Rev A
07/01/2020
OP Cmd Enable
Default: Yes
This setting determines if the unit will respond to “Open Protocol control” commands. These commands
are generally the ones that control unit operation or modify configuration. When this setting is set to
yes, all supported commands listed below are handled. When set to no, the following MID commands
will return an error:
• 0018 Parameter Select
• 0019 Parameter Batch Size
• 0020 Parameter Reset Batch
• 0038 Job Select
• 0039 Job Restart
• 0042 Tool Disable
• 0043 Tool Enable
• 0050 VIN Download
• 0082 Write Time
• 0127 Job Abort
• 0130 Job Off
• 0150 Multi ID Download
• 0156 Reset Latest Identifier
• 0157 Reset All Identifiers
Cell ID
Range: 0 to 9999
Default: 0000
This setting controls the value put in the Cell ID field of Open Protocol commands such as MID 0001 and
0061. The same Cell ID will be used for connections on all interfaces.
Channel ID
Range: 0 to 99
Default: 00
This setting controls the value put in the Channel ID field of Open Protocol commands such as MID 0001
and 0061. The same Channel ID will be used for connections on all interfaces.