TCV e2 User Manual
22 of 36
P/N 857414 Rev A
07/01/2020
524
Name
Data Type
Description
ARRAY of
STRUCT of:
Last tightening data for each of the 2 interfaces. Each array entry
corresponds to an interface.
Tightening ID
DINT
ID number of the last tightening
Time
SINT[6]
Timestamp of the last tightening
Reserved
INT
Reserved in this product. Set to 0.
Reserved
SINT
Reserved in this product. Set to 0.
Parameter
SINT
Number of the parameter that produced the tightening
Tightening Status
BOOL
Indicates if the last tightening was accepted as valid.
Count
SINT
Number of results performed in the current batch for the parameter.
Batch
SINT
Number of results required for a batch in the parameter.
Torque Unit
INT
Unit used for torque fields
Torque
REAL
Torque of the tightening just performed.
Min Torque
REAL
Minimum torque required for a tightening in the parameter.
Max Torque
REAL
Maximum torque required for a tightening in the parameter.
Angle
DINT
Angle of the tightening just performed.
Min Angle
DINT
Minimum angle required for a tightening in the parameter.
Max Angle
DINT
Maximum angle required for a tightening in the parameter.
Prevailing Torque
REAL
Prevailing torque of the tightening just performed.
Min Prevailing
Torque
REAL
Minimum prevailing torque required for a tightening in the parameter.
Max Prevailing
Torque
REAL
Maximum prevailing torque required for a tightening in the parameter.
Click Torque
REAL
Click torque of the tightening just performed.
VIN
SINT[25]
The VIN associated with the tightening.
Total size: 168 bytes