TCV e2 User Manual
12 of 36
P/N 857414 Rev A
07/01/2020
Status Info Group
Pressing
cycles through these screens:
•
VIN 1=
–
This screen will display the VIN associated to Interface 1.
•
VIN 2=
–
This screen will display the VIN associated to Interface 2.
•
Last Tightening
–
This screen will display the last torque event logged.
Network Connection Info Group
If no connections are active there will only be one sub-screen:
No active connections
IP Info Group
The IP Info Group provides the configuration options for the TCV e2. Pressing
or
cycles through
these screens:
•
Unit IP Address
•
Subnet Mask
•
Gateway
•
MAC Address
•
Qualifier Radio Info
Pressing ENT while on the Unit IP Address, Subnet Mask, or Gateway screens will activate the
PROGRAMMING screen which provides additional options. (The MAC address is assigned by the factory
and cannot be changed.) Changes to these settings only apply after the qualifier is restarted. The
settings in this page apply to all interfaces.
IP Address
Default: 192.168.1.67
This setting controls the IP address of the qualifier for Ethernet networks.
Subnet Mask
Default: 255.255.255.0
This setting controls the subnet mask for Ethernet networks.
Gateway
Default: 192.168.1.113
This setting controls the default gateway setting for Ethernet networks.
Edit Password
Default: 0104
The password is 4 numbers.
XBEE Channel
Default: 1
Range: 1 to 12
This setting controls which channel is used by the qualifier radio. All tools learned to the qualifier will be
set to this channel automatically as part of the learn process. In general, this setting does not have to be
changed, but if tool communication is not working reliably, changing this setting may improve
communication.