1. Cell ID
This command sets the Cell ID number reported by the unit in ACOP result messages.
Data: number of up to 4 digits (0-9999)
Example:
*%01%4305%*
This bar code would set the Cell ID of the unit to 4305.
2. Channel ID
This command sets the Channel ID number reported by the unit in ACOP result messages.
Data: number of up to 2 digits (0-99)
Example:
*%02%19%*
This bar code would set the Channel ID of the unit to 19.
3. Controller Name
This command sets the Controller Name of the unit.
Data: up to 25 characters
Example:
*%03%air - bag%*
T
his bar code would set the Controller name of the unit to “air
-
bag”.
4. VIN
This command sets the VIN or Identifier part 1 (VIN characters 1-25) reported by the unit in tightening
result messages, the ACOP MID 0052 Vehicle ID Number, and the ACOP MID 0152 Multiple identifier and
result parts notifications.
Data: up to 25 characters
Example:
*%04%VIN1234567%*
As mentioned above, a bar code is assumed to be a VIN number if the data is not in the command
format. As such, the same VIN could be provided as:
*VIN1234567*
6. Identifier part 2
This command sets the Identifier part 2 (VIN characters 26-50) reported by the unit in tightening result
messages and the ACOP MID 0152 Multiple identifier and result parts notifications.
Data: up to 25 characters
Example:
*%06%B23FJ9S3%*
7. Identifier part 3
This command sets the Identifier part 3 (VIN characters 51-75) reported by the unit in tightening result
messages and the ACOP MID 0152 Multiple identifier and result parts notifications.