TCV e2 User Manual
9 of 36
P/N 857414 Rev A
07/01/2020
Lock on batch
Default: no
This setting determines if the unit will lock or restart the parameter when a batch is completed. When
set to yes, the qualifier will stop when a batch is completed and transition to a no active parameter
state. When set to no, the qualifier will restart the parameter when a batch is completed.
TAC Fields
Mode
Default: Peak
Values: Peak, TAM
This setting controls the mode the tool uses to determine the torque.
Autoclear Time
Default: 1
Range: 0.0 to 9.9 seconds
Available Modes: all
This setting controls the amount of time the torque must be steady before it is reported.
Dwell Time
Default: 5.0
Range: 0.0 to 25.5 seconds
Available Modes: all
This setting controls the amount of time permitted for reseating the tool or ratcheting.
Head Length
Default: 36.50 mm
Values: 0 to 100 mm
Available Modes: all
This setting defines the common centerline length of the head used with the tool. If this value is not
entered correctly, torque measurements will be invalid.
Some standard head lengths based on capacity and head type are:
Torque Unit
Default: in.lb
Values: in.lb, ft.lb, N.m, cm.kg, m.kg, cNm
Available Modes: all
This setting controls the units of Min Torque and Max Torque, as well as the torque reported with each
tightening.
Snug Torque
Default: 10% of tool capacity
Range: 0 to Min Trq
Available Modes:TAM
This setting controls the torque threshold at which the tool starts measuring the angle.
Min Torque
Default: 10% of tool capacity