Order number: 900318.002 V0.31
Page 26
© Störk-Tronic 2021 • www.stoerk-tronic.com • Subject to modifications.
Parameter tables
T-- Operating hours
This level contains the storage and configuration for operating timers, which serve as indicators for maintenance. Those are represented
by T10 ... T34.
In order to reset the resetable timers, the service technician first needs to set
J42
to 1, and then select the timers to reset through T10.
The Fryer also offers 8 frying timers. Those may be linked to the basket control, and are configured through T40 to T88.
Para-
meter
Function
Range
T10
Reset operating hours
Service action requires unlocking through
J42
+1: Reset time since service
+2: Reset time K1
+4: Reset time K2
+8: Reset time K3
+16: Reset time K4
+32: Reset time K5
+64: Reset time K6
+128: Reset time Aout
+256: Reset time SSR1
+512: Reset time SSR2
+1024: Reset time SSR3
+2048: Reset oil Timer
T11
Total operating hours 0 ... 9999 + T12
-
T12
Total operating hours 10000 * 0 ... 9999 + T11
-
T13
Operating hours since last service 0 ... 9999 + T14
-
T14
Operating hours since last service 10000 * 0 ... 9999 + T13
-
T15
Operating hours K1 0 ... 9999 + T16
-
T16
Operating hours K1 10000 * 0 ... 9999 + T15
-
T17
Operating hours K2 0 ... 9999 + T18
-
T18
Operating hours K2 10000 * 0 ... 9999 + T17
-
T19
Operating hours K3 0 ... 9999 + T20
-
T20
Operating hours K3 10000 * 0 ... 9999 + T19
-
T21
Operating hours K4 0 ... 9999 + T22
-
T22
Operating hours K4 10000 * 0 ... 9999 + T21
-
T23
Operating hours K5 0 ... 9999 + T24
-
T24
Operating hours K5 10000 * 0 ... 9999 + T23
-
T25
Operating hours K6 0 ... 9999 + T26
-
T26
Operating hours K6 10000 * 0 ... 9999 + T25
-
T27
Operating hours Aout 0 ... 9999 + T28
-
T28
Operating hours Aout 10000 * 0 ... 9999 + T27
-
T29
Operating hours SSR1 0 ... 9999 + T30
-
T30
Operating hours SSR1 10000 * 0 ... 9999 + T29
-
T31
Operating hours SSR2 0 ... 9999 + T32
-
T32
Operating hours SSR2 10000 * 0 ... 9999 + T31
-
T33
Operating hours SSR3 0 ... 9999 + T34
-
T34
Operating hours SSR3 10000 * 0 ... 9999 + T33
-
T40
Timer config sel Timer 1
0: deactivated
1: Timer config 1 (T50 - T53)
2: Timer config 1 (T55 - T58)
3: Timer config 1 (T60 - T63)
4: Timer config 1 (T65 - T68)
5: Timer config 1 (T70 - T73)
6: Timer config 1 (T75 - T78)
7: Timer config 1 (T80 - T83)
8: Timer config 1 (T85 - T88)
0
T41
Timer config sel Timer 2
see T40
0