Order number: 900318.002 V0.31
Page 11
© Störk-Tronic 2021 • www.stoerk-tronic.com • Subject to modifications.
Parameter tables
Para-
meter
Functional description
Setting range
J1=0 J1=1
b21
Switching direction E1
0: Normally Open
1: Normally Closed
0
b22
Switching direction E2
see
b21
0
b23
Switching direction E3
see
b21
0
b24
Switching direction E4
see
b21
0
b25
Switching direction E5
see
b21
0
b26
Switching direction E6
see
b21
0
b33
Enable Frequency measurement E3
0: Digital input
1: Frequency measurement
0
b41
Key selection, function “SET”
0: Off
1: Key T1
2: Key T2
3: Key T3
4: Key T4
5: Key T5
6: Key T6
7: Key T7
4
b42
Key selection, function “UP”
see
b41
1
b43
Key selection, function “DOWN”
see
b41
2
b99
Password
-99 ... 999
0