Order number: 900318.002 V0.31
Page 6
© Störk-Tronic 2021 • www.stoerk-tronic.com • Subject to modifications.
Parameter tables
Bit
Name
Meaning
Error unit Notes
0x3B
b2s
Basket 2 Sensor Error
3
0x3E
oci
Oil check impossible
3
0x3F
ouq
User Question: Is oil or fat used?
3
Limiter modules
The limiter modules enable the user-defined monitoring of process parameters.
This device has 2 limiter modules. Limiter 1 is configured by
A10
...
A1A
, limiter 2 by
A20
...
A2A
.
Through a vast option of parameters like grace times, sensor selections, directions, etc., a great variety of user defined parameters may
be monitored.
Once the Limiters have sensor inputs, they record their minimum and maximum values since their last reset, enabling easy detection of
out of range operation, etc.
Consult the parameter list for further information
Error units
A list of the available error units, which may be adjusted by the user.
The error units aggregate errors with a similar severity in order to provide easier configuration to their behavior.
Error
unit
Parameter
for actua-
tors
Parameter for
acknowledge
Parameter
for repeat
Default actu-
ators
General meaning of this error unit
1
A80
A81
A82
Buzzer, Display,
warning (14)
Sensor Error, the device will switch into emergency operation
2
A83
A84
A85
Buzzer, Display,
error out
Operation of the device not possible, safety relevant Errors
3
A86
A86
A87
Buzzer, Display,
warning (14)
Operation impeded, but may continue
4
A89
A90
A91
-
Limiter modules
The device has 2 independent limiter modules, which may be used to monitor additional temperature conditions, with a variety of options.
There are 2 limiter modules available. The first one is configured by
A10
through
A1A
, the second one is configured by
A20
through
A2A
.
The limiters do also provide the ability to record minimum and maximum sensor values for diagnostics. These are handled by
A70
through
A75
.