Parameter tables
Para-
meter
Functional description
Setting range
J1=0 J1=1
U 1
Assignment relay K1
0: Deactivated
1: Always active
2: Heater 1 active
3: Deactivated
4: Energy controller On
5: Deactivated
6: Alarm sensor 1 low
7: Alarm sensor 1 high
8: Alarm sensor 2 low
9: Alarm sensor 2 high
10: Warning global
11: -Warning global
12: Error global
13: -Error global
14: Buzzer
15: Manual out U29
16: Reset heater controller
17: Control output heater loop 1
18: Control output loop 2
19: Basket Relay 1 down
20: Basket Relay 1 up
21: Basket Relay 2 down
22: Basket Relay 2 up
23: Heater SW PWM
24: Heater Analog PWM with Min on/off times
25: Heater to off/on with protection times
26: Limiter 1 enable out
27: Limiter 2 enable out
28: Filtration valve out
24
U 2
Assignment relay K2
see
U1
0
U 3
Assignment relay K3
see
U1
0
U 4
Assignment relay K4
see
U1
0
U 5
Assignment relay K5
see
U1
0
U 6
Assignment relay K6
see
U1
0
U20
Analog out analog mode
This effects the scaling, if set to the used variety, the output
will be more accurate
0: 0 ... 10V
1: 4 ... 20 mA
0
U21
Analog mode SSR1
0: PWM
1: frequency
0
U22
Min. Freq SSR1
0.0 ...
U23
Hz
5.0
U23
Max Freq SSR1
U22
... 200.0 Hz
15.0
U24
Off Freq SSR1
0.0 ... 200.0 Hz
0
U25
Err Freq SSR1
0.0 ... 200.0 Hz
2
U29
Manual value analog output
0.0 ... 100.0%
0.0
U30
Assignment analog output 0 ... 10V/4 ... 20mA
see
U1
17
U31
Assignment SSR1
see
U1
17
U32
Assignment SSR2
see
U1
24
U33
Assignment SSR3
see
U1
0
U34
Assignment Burner on signal Modbus
see
U1
0
U35
Assignment Fan power signal Modbus
see
U1
0
U36
Assginment Reset signal Modbus
see
U1
0
U41
Function mode SSR1
0: Digital
1: Analog, see
U21
1
U42
Function mode SSR2
0: Digital
1: PWM
1