Parameter tables
A--
Alarms
Overview
The controller has several error units. Those have Error inputs (i.e. Sensor 1 short circuit), which trigger them.
Each Error Type will activate it‘s associated actuators to provide the actual error handling to the system.
If the error has been acknowledged by the user and the error cause is not removed, the units may be configured to re-raise the error to
the user and the system.
Error sources
The errors the controller may generate:
Bit
Name
Meaning
Error unit Notes
0x00
F1L
Value of Sensor 1 below valid range
1
0x01
F1H
Value of Sensor 1 above valid range
1
0x02
F2L
Value of Sensor 2 below valid range
1
0x03
F2H
Value of Sensor 2 above valid range
1
0x04
F3L
Value of Sensor 3 below valid range
1
0x05
F3H
Value of Sensor 3 above valid range
1
0x06
F4L
Value of Sensor 4 below valid range
1
0x07
F4H
Value of Sensor 4 above valid range
1
0x08
F5L
Value of Sensor 5 below valid range
1
0x09
F5H
Value of Sensor 5 above valid range
1
0x0A
F6L
Value of Sensor 6 below valid range
1
0x0B
F6H
Value of Sensor 6 above valid range
1
0x10
ba
Burner Alarm
2
0x11
ovr
External over temp
2
0x12
low
External Low gas
2
0x13
mce
Main controller error
3
0x15
ooe
Oil old error
3
0x16
oae
Oil amount error
3
0x17
ohi
Oil overheat
3
0x18
hhi
Wall overheat
3
0x19
heu
Heating element up
4
0x1A
b1l
Basket 1 stuck error
3
0x1B
b2l
Basket 2 stuck error
3
0x1C
mer
Modbus exception received
3
0x1D
mto
Modbus F93 (burner did not answer)
3
0x1E
EP1
EEPROM Parameter invalid
6
0x1F
EP2
NVRAM Parameter invalid
6
0x20
A1L
see A1A
0x21
A1H
see A1A
0x22
A1B
see A1A
0x23
A2L
see A2A
0x24
A2H
see A2A
0x25
A2B
see A2A
0x30
t1s
Timer 1 Sensor Error
3
0x31
t2s
Timer 2 Sensor Error
3
0x32
t3s
Timer 3 Sensor Error
3
0x33
t4s
Timer 4 Sensor Error
3
0x34
t5s
Timer 5 Sensor Error
3
0x35
t6s
Timer 6 Sensor Error
3
0x3A
b1s
Basket 1 Sensor Error
3