Cable colour sequence:
green blue red black
Step 1
Step 2
Step 3
5. Performing a rotation test: the test is performed on the motor
connector with 4 cables. Remove the motor cover. Discon-
nect the pump from the drive. Check the motor function by
fitting a bridge to pins 1 and 2. Turn the motor fan at about 2
revs per second. You should feel some resistance against the
movements. If you cannot feel any resistance, you will need to
replace the motor. Repeat the test for pin combinations 1 + 3
and 2 + 3. Pin 4 (the green wire) is not used for this test. If all
rotation tests are positive, then proceed with step 6.
6. Check for current: perform the test on the large motor connector
with 4 cables: there must not be any current between pin 4 (earth
wire) and the other three cables. If this test fails, replace the motor.
7. Check the thermostat: disconnect the thermostat wires (yellow)
at the connector. Set your multimeter to ohms: the resistance
should be 3.9 kohms.
The display shows CODE
06
The status indicator on the
controller card repeatedly
flashes six times
Allow the spra-
ying device to
cool down. If the
spraying device
then runs, you
must remedy the
cause of overhe-
ating. Set up the
spraying device at
a cooler location
with good venti-
lation. Make sure
that the motor
air intake is not
blocked. If the
spraying device
still fails to start
up, follow step 1.
NOTE:
The motor must cool down for this test.
6. Check the overheating protection connector (yellow wires) on
the controller card.
7. Disconnect the overheating protection connector from the
socket on the controller card. Make sure the contacts are clean
and undamaged. Measure the overheating protection resi-
stance. If the measured value is not normal, replace the motor.
Check the thermostat:
disconnect the thermostat wires (yel-
low) at the connector. Set your multimeter to ohms: the resi-
stance should be 3.9 kohms.
8. Reconnect the overheating protection connector to the socket
on the controller card. Reconnect the power cable; switch the
spray device ON, and turn the pressure regulator knob clock-
wise half a turn. Replace the controller card if the spray gun
still does not start up.
The display shows CODE
08
The status indicator on the
controller card repeatedly
flashes eight times
Check the power
supply on the
spraying device
(the supply vol-
tage is too low to
operate the spra-
ying device).
1. Switch the spraying device OFF and unplug the power cable
from the device.
2. Disconnect any other devices connected to the same power cir-
cuit.
3. Locate a power supply that is working properly to avoid damage
to the electronics.
Original instruction
Содержание Airless SL 1600 HD
Страница 1: ...Airless SL 1600 HD SL 1600 HD Plus DE NL FR IT GB CZ...
Страница 31: ...31 Steuerung bersetzung der Originalanleitung...
Страница 33: ...33 Farbstufe bersetzung der Originalanleitung...
Страница 75: ...75 Besturing Vertaling van de originele handleiding...
Страница 77: ...77 Verftrap Vertaling van de originele handleiding...
Страница 119: ...119 Commande Traduction des instructions d origine...
Страница 121: ...121 Nuancement des couleurs Traduction des instructions d origine...
Страница 163: ...163 Comando Traduzione delle istruzioni originali...
Страница 165: ...165 Stadio di colore Traduzione delle istruzioni originali...
Страница 207: ...207 Control unit Original instruction...
Страница 209: ...209 Paint stage Original instruction...
Страница 251: ...251 zen P eklad origin lu n vodu...
Страница 253: ...253 Barevn stupe P eklad origin lu n vodu...
Страница 266: ...266...
Страница 267: ...267...