Instruction Manual
1
Model AZ3 HTE2
Test Transfer Efficiency according to EN 13966-1
Authority IPA Fraunhofer Institut
Date 28/03/2008
T
ransfer efficiencies achieved with the materials detailed in the test report were:
Certification available on www.airgunsa.com
THREE COAT SYSTEM
PRIMER
87 %
BASECOAT
83 %
CLEARCOAT
74 %
ANEST IWATA ITALIA S.r.l.
46, Corso Vigevano 10155, Torino
• ITALY
Tel. d39 011 - 24 80 868 Fax: +39 011 - 85 19 44
www.anest-iwata.it
ANEST IWATA Iberica
Calle de Les Teixidores, 3-5
08918 - Badalona (Barcelona)
• SPAIN
Tel.:+34 933 20 59 93 Fax.:+34 933 20 59 65
www.anest-iwata.es
ANEST IWATA Deutschaland
Mommsenstrasse 5, 04329 Leipzig
• GERMANY
Telefon: +49 0341 2414430 Fax: +49 0341 2525595
www.anest-iwata.de
ANEST IWATA Scandinavia
Ögärdesvägen 6C, 433 30 PARTILLE
• SWEDEN
Tel. +46 (0)31 - 340 28 60 Fax +46 (0)31 - 340 28 69
www.anest-iwata.se
ANEST IWATA France
25 rue de Madrid
38070 St Quentin Fallavier
• FRANCE
Tél. +33 (0)4 - 74 94 59 69 Fax +33 (0)4 - 74 94 34 39
www.anest-iwata.fr
ANEST IWATA U.K.
Unit 10 Little End Road - Eaton Socon
St. Neots - CAMBRIDGESHIRE
• U.K.
PE19 8JH
Tel.: +44 (0) 1480 405419 Fax: +44 (0) 1480 217610
www.anest-iwata.co.uk
ANEST IWATA Europe S.r.l.
46, Corso Vigevano 10155, Torino
• ITALY
Direct Tel. +39 011 - 22 74 402
Fax +39 011 - 22 74 400
www.anest-iwataeu.com
ANEST IWATA USA, Inc.
9920 Windisch Road,
West Chester, OH 45069
• USA
Tel: +1 513.755.3100 Fax: +1 513.755.0888
Toll Free: 800.440.0282
[email protected] www.anestiwata.com
Cormack ANEST IWATA
Unit 3, 10 Boden Road,
SEVEN HILLS NSW 2147
• AUSTRALIA
Tel: +61 2 9853 2000
Fax: +61 2 9853 2090
[email protected] www.anest-iwata.com.au
Contacts:
ANEST IWATA Group
Quality Air Spray Guns Since 1944
www.air-gunsa.com
Air Gunsa S.r.l. • ITALY
46, Corso Vigevano 10155 Torino
Tel. +39 011 - 24 80 868
Fax +39 011 - 22 74 406
W5AZ3HTE2_Re
v.09
ALWAYS observe WARNINGS and CAUTIONS in this
instruction manual.
TECHNICAL SPECIFICATIONS
Manufactured by: AIR GUNSA s.r.l,
46 Corso Vigevano 10155 Torino - Italy
This AIR GUNSA spray guns kit complies to
ATEX regulations 94/9/EC, protection level:
II 2 G X Suitable for using Zones 1 and 2.
X marking: Any static electricity discharge from the spray gun is to be diverted
to the ground via the conductive air hose as stipulated.
SPRAY GUN AZ3 HTE2, AZ3 HTE2 AV, AZ3 HTE2 HVLP
Before use, adjustment or maintenance, it is important
to read this instruction manual very carefully. This manual
must be stored in a safe place for any future reference.
GB
SAFETY WARNING
FIRE AND EXPLOSION
1. Never use the following HALOGENATED HYDROCARBON SOLVENTS:
which can cause cracks or dissolution of gun body (aluminium) due to
chemical reaction. UNSUITABLE SOLVENTS: methyl chloride, dichloro-
methane, 1.2-dichloroethane, carbon tetrachloride, trichloroethylene,
1.1.1-trichloroethane
2. Sparks and open flames are strictly prohibited.
Paints can be highly
flammable and can cause fire. Do not expose to open flames, electrical
goods, cigarettes etc.
3. Securely ground spray gun using conductive air hose.
(Less than 1M
Ω
)
Always ensure that the spray gun is earthed correctly.
PROTECTION OF HUMAN BODY
1. Use in a well-ventilated site, using a spray booth.
Poor ventilation can cause organic solvent poisoning and fire.
2. Always wear protective gear (safety glasses, mask, gloves) to avoid
inflammation of eyes and skin.
In case of any physical discomfort, immediately seek medical advice.
3.
Noise level can exceed 85dB(A),
wear earplugs if necessary.
4. Pulling the trigger many times during operation, may cause carpal
tunnel syndrome
. Always rest, in case of tiredness.
IMPROPER USE
1. Never point gun towards people or animals.
2. Never exceed maximum working pressure or maximum operating
Temperature
3. Always release air and fluid pressure before cleaning, disassembling
or servicing.
Otherwise, remaining pressure can cause bodily injury due
to improper operation or scattering of cleaning liquid.
4. Tip of fluid needle set has a sharp point.
Do not touch the tip during maintenance to avoid accidents.
5. Never use this gun to spray foods or chemicals.
Otherwise, foreign substance, could cause corrosion of fluid passages
which could adversely affect health.
HOW TO USE
CAUTION
- Use clean air filtered through air dryer and air filter.
- When using this gun for the first time after purchase, adjust fluid nee-
dle packing nut, spray cleaner to clean fluid passages and remove rust
preventive oil.
1. Firmly connect an air hose to air nipple 1/4”.
2. Firmly connect a suitable cup to fluid nipple.
3. Flush fluid passages with a compatible solvent.
4. Pour paint into container, test spray, adjust fluid output and pattern width.
HOW TO OPERATE
Suggested atomizing air pressure varies according to each model, and it
is listed in the Technical Data table.
Paint viscosity differs according to paint property and painting conditions.
12 to 23 sec. / Ford cup#4 is recommended.
Set the spray distance from the gun to the work piece, as near as possi-
ble within the range of 100-200 mm (3.9-7.9 in).
HEADQUARTERS:
ANEST IWATA Corporation
3176, Shinyoshida-cho, Kohoku-ku - Yokohama, 223-8501 JAPAN
* Measuring point: 1m backwards from gun, 1.6m height ** Weight without cup.
Max. working air pressure: 7.0 bar (100 PSI) Air connection: G 1/4”M
Noise Level (LAeqT)*: 77.6 dB (A) Fluid connection: G 1/4”F
Max. Temperature range: 5 ~ 40 °C Weight g (lbs)**: 517 (1.14)
Model
Nozzle
orifice
ø mm
Air cap set
mark
Air pressure
at gun inlet
bar (psi)
Fluid
output
ml/min
Air
consumption
Nl/min (cfm)
Pattern
width
mm (in)
AZ3 HTE2 / AZ3 HTE2 AV Gravity feed
HTE 2 1.0 1.0 (0.039)
10-15
HTE
2.0 (29)
80
200 (7.06)
180 (7.08)
HTE 2 1.3 1.3 (0.051)
140
240 (9.44)
HTE 2 1.5 1.5 (0.059)
160
260 (10.23)
HTE 2 1.8 1.8 (0.070)
18-20
HTE
250
215 (7.59)
300 (11.81)
HTE 2 2.0 2.0 (0.079)
300
340 (13.38)
HTE 2 2.5 2.5 (0.098) 25 HTE
3.0 (44)
450
280 (9.89) 360 (14.17)
HTE 2 2.8 2.8 (0.110)
28-30
HTE
540
300 (10.59)
380 (14.96)
HTE 2 3.0 3.0 (0.118)
560
400 (15.74)
HTE 2 3.5 3.5 (0.138) 35 HTE
600
420 (16.53)
AZ3 HTE2 AV HVLP Gravity feed
The HVLP spray guns follows all compliant HVLP mandates. Follow the indications of
the inlet air pressure to achieve atomizing pressure of 0.7 bar (10 PSI) at the center of
the air cap.
HTE 2 HVLP 1.3 (0.051)
HVLP
2.0 (29)
Air cap press.
0.7 bar (10 psi)
150
340 (12.0)
280 (11.0)
HTE 2 HVLP 1.5 (0.059)
185
290 (11.4)
HTE 2 HVLP 1.8 (0.070)
215
340 (13.4)
HTE 2 HVLP 2.0 (0.079)
240
360 (14.2)