4.7.2 How to do this
1. Connect the PA15 to the battery leads with the correct polarity (A+ /
A-).
2. Connect the consumer device (lamp) to the load output (L+ / L-) on
the PA15.
3. To configure the PA15 for this operating mode, plug in the
“NIGHTLIGHT” jumper.
Nightlight
Buzzer
SOC
Manager
Solar
Manager
Excess
4. No further settings on the PA15 are required. The adjusting
controller positions “P1” and “P2” are ignored in this operating
mode.
P1
P2
Position not
relevant !
Position not
relevant !
15 A
A+ A- S
S L+ L-
Solar
Manager
Exc ess
SOC
Manager
Nightlight
Buzzer
PA 15
P1
P2
5. In order to set up the time-controlled function, the Solarix
Tarom/Powertarom must be programmed accordingly.
Please consult the operating manual for the Solarix Tarom for more
details.
5 Help with troubleshooting
-
Fuse faulty
The fuse is not normally triggered without a reason. In this event,
please check the device installation before inserting the new fuse.
Use only equivalent fuses to replace old ones.
The following reasons can result in a fuse being blown:
-
The consumer device or the cabling to the consumer has
caused a short-circuit.
Correct the short-circuit and install a new fuse
-
The polarity on the battery is reversed or it has been
connected to the wrong terminals.
PA15 TTS Operating Manual
Page 28
Disconnect the battery and connect with the correct polarity,
insert a new fuse.
Содержание PA 15