The inherent safety measures in the design of the remote switch can be 
impaired or deactivated if the switch is operated in a way not specified by 
the manufacturer. 
 
Please ensure, therefore, that the connected loads and performance 
characteristics given in the “Technical data” section are observed. 

3  Installing the Steca PA15 TTS remote switch 

3.1  Precautions 

Do not install or operate any PV components in areas where flammable 
gas mixtures may occur! 
Explosive oxyhydrogen gas may be generated in the vicinity of the battery. 
For this reason, ensure good ventilation around the battery and avoid 
sparking! 

 

The following legal regulations for batteries must be observed: 

  DIN VDE 0510 Part 2, Sections: 

 7. Precautions against the risk of explosion 

 8. Precautions against dangers from electrolytes (sulphuric acid) 

 9. Positioning 

  National Electric Code including Article 690 

3.2  Choosing the installation site 

The Steca PA15 must be connected to the battery and the consumer 
devices. As the line losses and therefore also the voltage drops need to be 
kept as low as possible, the PA15 must be installed in such a way that the 
cable paths selected are as short and direct as possible. The line lengths 
to the consumer equipment can only be affected in a minimal way as on-
site distribution is required.  
 
The PA15 must not be installed in areas where there are flammable liquids 
or gases. Installation is only permissible in an area with sufficient 
protection classification for the PA15 (see Technical data). The minimum 
and maximum permissible ambient temperatures must always be 
observed at the installation site. In addition, the PA15 must not be installed 
or operated in humid conditions (e.g. bathrooms), or in rooms where 
flammable gas mixtures may occur, e.g. from gas cylinders, paint, varnish, 
solvents, etc.  
 
The remote switch must be protected against the direct effects of the 
weather. Direct sunlight and heating from to neighbouring devices must be 
avoided.  

 

Batteries and the PA15 must be installed in a position inaccessible to 
children and unauthorised persons. No arrangements should therefore be 
made to provide access to the PA15 by unauthorised persons. 

PA15 TTS Operating Manual 

Page 6

 

Содержание PA 15

Страница 1: ...Operating Manual Remote control Steca PA 15 703 639 V 04 04 09 46 PHOTOVOLTAIK PHOTOVOLTAIC PHOTOVOLTAIQUE FOTOVOLTAICA EN...

Страница 2: ...nd commissioning 9 3 4 1 Connecting the PA15 to the DC system 9 3 4 2 Connecting the consumer equipment 9 3 5 Disassembly 9 3 6 Safety measures 9 3 6 1 Fuse in the PA15 10 3 6 2 Flammability 10 3 6 3...

Страница 3: ...24 4 5 4 Safety function when reception fails 24 4 6 Excess management excess 25 4 6 1 What does this mean 25 4 6 2 How to do this 25 4 6 3 Special features using the button switch 26 4 6 4 Safety fun...

Страница 4: ...y instructions and damage exclusions Steca GmbH and it suppliers cannot accept any liability for any damage or losses arising as a result of the use of this manual Steca GmbH and it suppliers cannot a...

Страница 5: ...sfer of ownership 2 3 General safety instructions For your safety it is essential that the following points are observed during assembly work Avoid any sparking in all working procedures Solar modules...

Страница 6: ...ses and therefore also the voltage drops need to be kept as low as possible the PA15 must be installed in such a way that the cable paths selected are as short and direct as possible The line lengths...

Страница 7: ...iring work can be started once the PA15 has been mechanically installed 3 2 2 Mounting the remote switch The device can be used as a template in order to mark out the mounting holes Only use the PA15...

Страница 8: ...attery for the solar system A short circuit in the battery must be avoided at all costs This could result in the PA15 and the battery being destroyed Please therefore ensure that the rechargeable batt...

Страница 9: ...terminal A Connect the minus pole on the power lead to terminal A Insert the fuse into the PA15 When the device has been correctly connected to the supply lead a short beep will be emitted to indicate...

Страница 10: ...ntroller and the remote switch has been installed on an incombustible base 3 6 3 Fuse protection A fuse protects the PA15 against single faults e g load short circuit battery reverse polarity reverse...

Страница 11: ...he installation engineer The losses in safety extra low voltage status caused by earthing must be compensated by the corresponding insulation measures on active parts protection against direct contact...

Страница 12: ...will prevent the entire device from functioning 4 The operating modes The remote switch has various operating modes It can be custom configured depending on the function required The sections below de...

Страница 13: ...function first needs to be enabled The PA15 does not need to be installed for this purpose Proceed as follows Commission the TAROM POWERTAROM charge controller in accordance with the instructions in t...

Страница 14: ...the system e g load shut off During data transfer the power consumption of the TAROM POWERTAROM charge controller increases for a short time For this reason this mode should be deactivated if not bei...

Страница 15: ...e BUZZER bridge The buzzer will then output a warning signal 10 times before the load is shut off over a total period of around 1 minute Nightlight Buzzer S OC Manager S olar Manager Excess 4 Then set...

Страница 16: ...rom the far left 0 turn 4 beeps to the right 4 SOC values between 10 and 99 can be set on the scale from 0 9 0 SOC between 0 9 10 beep 1 SOC between 10 19 20 beep beep 8 SOC between 80 89 80 beep 9 SO...

Страница 17: ...he shutdown threshold on P1 has not yet been reached this button can be used to switch the load break switch on the PA15 on and off manually just like a remote control switch Multiple buttons can also...

Страница 18: ...ager Nightlight Buzzer PA 15 Battery wires Last S hunt HS200 RJ 48 S tart signal Out Out Diesel wind water etc G 4 4 1 What does this mean In this operating mode the PA15 can supply a start signal for...

Страница 19: ...A A 2 Connect the load output L L to the start input for the generator if this is possible directly Otherwise a suitable signal converter is required e g relay 3 To configure the remote switch for thi...

Страница 20: ...will be started if the SOC is below 40 If this value is reached the PA15 will connect its load output to the battery until the shut down threshold of P1 is reached The beep signals the transition betw...

Страница 21: ...r should be used Before connecting the TTS to your generator ensure that the instructions for using the generator are observed For the Tarom charge controller to be able to record the additional gener...

Страница 22: ...c G 4 5 2 How to do this The TAROM regularly sends certain identifiers to the PA15 TTS remote switches connected which tell the remote switches which solar arrays should work with the battery and whic...

Страница 23: ...ys can be included in the system P1 P2 Position not relevant Solar generator identifier 15 A A A S S L L Solar Manager Excess SOC Manager Nightlight Buzzer PA 15 P1 P2 The additional generator with th...

Страница 24: ...to switch the PA15 output on and off manually just as with a remote control switch A switch permanent contact can be used to switch generators on and off using the PA15 regardless of the control The l...

Страница 25: ...an be used by an excess consumer device e g water pump The TAROM switches on the excess consumer via the PA15 when the battery is fully charged before the solar current in the battery is shut off 4 6...

Страница 26: ...ower for as long as the button is depressed If you want to the consumer to be operated permanently in this situation use a switch permanent contact instead of the button momentary contact 4 6 4 Safety...

Страница 27: ...n your standalone network The Solarix TAROM POWERTAROM has a few additional settings to control the nightlight function The corresponding configuration menu in the charge controller can be used to set...

Страница 28: ...p the time controlled function the Solarix Tarom Powertarom must be programmed accordingly Please consult the operating manual for the Solarix Tarom for more details 5 Help with troubleshooting Fuse f...

Страница 29: ...function of the device is OK If the fuse blows or if there is no acoustic signal despite the correct operating voltage there is a fault in the device Can the consumer device be switched on and off ma...

Страница 30: ...ion of the PA15 according to the instructions in the No function section The basic requirement is that the battery data transfer in the TAROM POWERTAROM is activated see section 8 2 The correct recept...

Страница 31: ...n in section 8 6 Solar manager Please also observe the instructions under point PA15 is not receiving any data Excess manager is not working Check the basic function of the PA15 according to the instr...

Страница 32: ...re is described in section 8 2 of this manual The PA15 TTS remote switch forms part of the TAROM power management system It is a data controlled remote switch for switching consumer devices and genera...

Страница 33: ...The nightlight function on the charge controller Programmable external exhaustive charge protection What is know as an excess manager Or as a generator manager The device is configured with a 5 fold...

Страница 34: ...ting modes can be found in the sections below When turning the controller an acoustic return message will be emitted to facilitate the positioning process The acoustic signal will always be emitted wh...

Страница 35: ...n the system battery being overloaded The operating modes The Steca PA15 TTS remote switch has different operating modes Depending on the function required the operating mode in question needs to be s...

Страница 36: ...ld can also be set here The jumper setting must not be changed for this operating mode The only point to ensure here is that the switching threshold is set using P1 In this operating mode the value fo...

Страница 37: ...created using a suitable switching element relay contactor which in turn can be controlled by the output on the PA15 In order to prevent reverse current from the battery into the solar generators at...

Страница 38: ...n A one off reception of the data is sufficient as the shutdown criterion however By connecting an external button the consumer can always be switched on and off manually during excess operation Outsi...

Страница 39: ...ible pulse duration determined by the fuse used max 10us Overcurrent protection 15 A flat fuse Reverse polarity protection Reverse polarity protection diode fuse Receiver Superhet principle Data rate...

Страница 40: ...703639...

Отзывы: