PA15 TTS Operating Manual
Page 13
When the load output on the remote switch is triggered, the
consumer equipment connected can be switched on and off using
the button, just as with a remote-control switch. When the load output
on the PA15 is blocked, the load output is only triggered for as long
as the button is depressed. If an option for manual override is
required for the PA15, a switch (permanent contact) can be
connected to these terminals.
4.2 Release for the data transfer on the SOLARIX TAROM /
POWERTAROM
The Steca PA15 TTS remote switch can only be operated in
combination with SOLARIX TAROM 235, TAROM 245, TAROM 430
or POWERTAROM solar charge controllers, software version 12.15
and higher.
On delivery, the data transfer function is deactivated on TAROM /
POWERTAROM solar charge controllers. To be able to use the
PA15, the transfer function first needs to be enabled.
The PA15 does not need to be installed for this purpose.
Proceed as follows:
•
Commission the TAROM / POWERTAROM charge controller
in accordance with the instructions in the relevant installation
manual.
•
Press any key to access the first menu level.
•
Then press the two outermost buttons on the TAROM/
POWERTAROM simultaneously; this will take you to the
“OPTION TRANSMIT” menu.
•
Press the OK button in the “OPTION TRANSMIT” menu to
view the current setting.
•
Use the UP / DOWN buttons to select the “AKKU” (BATTERY)
mode and confirm by pressing the OK button.
•
The setting will now be saved, even when the Tarom /
Powertarom is not operational.
•
This function can only be enabled by selecting “AKKU”
(BATTERY); no data will be sent to the receiver in the “PC”
and “OFF” positions.
•
The “PC” option is used for servicing purposes by the
manufacturer only and cannot be used.
Once the data transfer function has been enabled using the “AKKU”
option, the Tarom / Powertarom start transferring one data packet to the
battery lead about once a minute.