If the data transfer is interrupted or not activated in the Tarom, the
output remains or becomes enabled, thus ensuring the operational
safety of the consumer device.
If the data transfer is interrupted, the button / switch can be used to
switch the consumer on or off manually.
The buzzer does not indicate an interruption in the data transfer.
In the shutdown early warning phase, all the changes in the settings
are ignored, i.e. the acoustic return message is also deactivated
when the controller is adjusted. If the jumper for the buzzer is
removed during the warning phase, it will NOT be deactivated
either!
The warning for invalid settings remains active at all times.
4.4 Generator manager (SOC MANAGER P1 > P2)
PA15 TTS Operating Manual
Page 18
-
-
Switc h
Relay
-
-
Solar m odule
Tarom c ontroller
15 A
A+ A- S
S L+ L-
Solar
Manager
Exc ess
S
Ma
OC
nager
Nightlight
Buzzer
PA 15
Battery wires
Last
+
Shunt HS 200
RJ 48
+
-
Start
signal
Out
Out
(Diesel
wind
water
etc...)
G
4.4.1 What does this mean?
In this operating mode, the PA15 can supply a start signal for an
emergency generating set, depending on the load status of the
battery. If the SOC falls below a certain value, the generator will be
started via the load output on the PA15 TTS remote switch to
recharge the battery.
With this function, the PA15 provides a continuous switching signal
to its output for as long as the condition set is fulfilled. The
amplitude of this signal corresponds to the system voltage and
relates to the battery plus potential.
Before using this operating mode, it is essential to ensure that the
switching signal supplied by the PA15 is suitable for the generator
to be started!
Depending on the requirements, it may be necessary to modify the
switch signal via additional components, e.g. relays.
These components do not form part of the Steca PA15 TTS remote
switch and must be purchased and installed as an extra.