PA15 TTS Operating Manual
Page 38
the excess consumer will be shut down once again in order to keep the
battery at full charge.
The current which the excess consumer is permitted to pick up to ensure
that the battery voltage does not fall below the threshold value, depends
on the overall system and needs to be determined experientially.
With changing light incidence in particular, frequent switching on and off of
the excess consumer may occur!
Typical excess consumers include: pumps for garden ponds or air
conditioning units.
Safety functions:
If no data is received, the excess consumers are switched off as the
system battery should not be discharged unnecessarily.
To provide additional data security, the excess message must be received
3 times before an excess consumer is switched on. A one-off reception of
the data is sufficient as the shutdown criterion, however.
By connecting an external button, the consumer can always be switched
on and off manually during excess operation.
Outside this range, the consumer can only be switched on by pressing the
button continuously or using a switch.
Nightlight function
The settings on the receiver are ignored, and the remote switch will only
react to the night signal. If “night” is signalled by the controller, the remote
switch will be activated.
Safety functions:
If no data is received, the lamps connected are switched off as the system
battery should not be discharged unnecessarily (during the day).
The nightlight message must be received 3 times before the consumer is
switched on or off.
By connecting an external button, the consumer can always be switched
on and off manually during nightlight operation.
If there is no nightlight signal, the consumer can only be switched on by
pressing the button continuously or using a switch.
Содержание PA 15