PA15 TTS Operating Manual
Page 34
Assigning the switching thresholds to the SOC value for P1 and P2, for the
relevant operating mode:
Value | relevant SOC range | identifier
0:
0 .. 9 % SOC
solar generator / identifier 0
1:
10 .. 19 % SOC
solar generator / identifier 1
2:
20 .. 29 % SOC
solar generator / identifier 2
3:
30 .. 39 % SOC
solar generator / identifier 3
4:
40 .. 49 % SOC
solar generator / identifier 4
5:
50 .. 59 % SOC
solar generator / identifier 5
6:
60 .. 69 % SOC
solar generator / identifier 6
7:
70 .. 79 % SOC
solar generator / identifier 7
8:
80 .. 89 % SOC
solar generator / identifier 8
9:
90 .. 99 % SOC
solar generator / identifier 9
The switching thresholds can be set using the scale. The switching
thresholds to be set each represent an SOC value or an identifier.
The current SOC value or identifier transferred by the Tarom is compared
in the PA15 to the settings on controllers P1 and P2 and a switching
function is run in accordance with the operating mode configuration
selected.
The procedures for operating the adjusting controllers in the various
operating modes can be found in the sections below.
When turning the controller, an acoustic return message will be emitted to
facilitate the positioning process. The acoustic signal will always be
emitted when changing between two settings. For example, when turning
the indicator from position 0 to position 1, the change from 0 to 1 is
signalled by a beep.
For example, if you want to change from position 0 to position 6, you will
hear six beeps.
If the two controllers are set to the same value, a continuous alarm signal
will be sounded as this is a non-permissible state. As a general principle,
the shutdown value cannot be the same as the activation value.
The device also permits an external button to be connected. This button
has different functions depending on the operating mode. For a more
detailed description of the button functions, please see the sections below.
For acoustic signalling, the receiver has a buzzer which provides an
audible warning when the load is about to be switched off. This buzzer
function is only active in the SOC manager operating mode.
If transmission is possible between Tarom and PA15 or even only partially
distorted, specified safety functions will be active which shut down the