3-14
PMW-EX3
Item7: Diagnosis between image processor and display blocks
Diagnosis between Image processor and Display blocks analyzes the following contents.
ID
Diagnosis description
Error value
Type 1/2
Note
0x80
Video signal line test
-1: Test pattern checking failure
1, 2
Conducts a test from camera
signal processor IC to base band
processing IC. Monitor output
images will be distorted during
the test.
When an error is detected, it indicates a possible failure in the chip or the signal line between chips.
Item8 to 13: Diagnosis between display and media blocks
Diagnosis between display and media blocks analyzes the following contents.
Item No. ID
Diagnosis description
Error value
Type 1/2
Note
8
0x90
Video signal line communication
-1: Test pattern checking failure
1, 2
_
test in recording direction (in the
-2: Sequence error
direction from base band processing
IC to AVIT signal processing IC)
9
0x91
Video signal line communication
-1: Test pattern checking failure
1, 2
_
test in playback direction (in the
-2: Sequence error
direction from AVIT signal processing
IC to base band processing IC)
10
0x92
LPCM signal line communication
-1: Test pattern checking failure
1, 2
_
test in recording direction (in the
-2: Sequence error
direction from base band processing
IC to AVIT signal processing IC)
11
0x93
LPCM signal line communication
-1: Test pattern checking failure
1, 2
_
test in playback direction (in the
-2: Sequence error
direction from AVIT signal processing
IC to base band processing IC)
12
0x94
4bit I/F signal line communication
-1: Test pattern checking failure
1, 2
_
test in recording direction (in the
-2: Sequence error
direction from base band processing
IC to AVIT signal processing IC)
13
0x95
4bit I/F signal line communication
-1: Test pattern checking failure
1, 2
_
test in playback direction (in the
-2: Sequence error
direction from AVIT signal processing
IC to base band processing)
When an error is detected, it indicates a possible failure in the chip or the signal line between chips.
4. Executing Log Dump
Executing Log Dump acquires the error log information and saves it to the active, writable media.
Select Log Dump under the INFORMATION menu, and execute it with Execute. The process is complete
when “Log Dump Done” is displayed as a result. Do not remove the media until this message appears.
Содержание XDCAM EX PMW-EX3
Страница 1: ...SOLID STATE MEMORY CAMCORDER PMW EX3 SERVICE MANUAL 1st Edition Revised 1 ...
Страница 4: ......
Страница 80: ......
Страница 96: ......
Страница 100: ...5 4 PMW EX3 BTP2 6 x 8 BTP2 6 x 8 BTP2 6 x 8 51 52 57 58 54 53 55 62 61 60 59 56 Pad Block ...
Страница 174: ......
Страница 188: ......
Страница 224: ...8 36 PMW EX3 8 36 2 3 4 5 A B C D E F G H 1 ...
Страница 230: ...8 42 PMW EX3 8 42 2 3 4 5 A B C D E F G H 1 ...
Страница 254: ...8 36 PMW EX3 8 36 2 3 4 5 A B C D E F G H 1 ...
Страница 260: ...8 42 PMW EX3 8 42 2 3 4 5 A B C D E F G H 1 ...
Страница 296: ......
Страница 313: ......
Страница 314: ...Printed in Japan Sony Corporation 2009 2 16 2008 PMW EX3 UC E CE CN E 9 968 446 02 ...