Restart SMS Server
Chapt
er 1 Us
e
r Guid
e
for anything from 3 minutes to 15 minutes. When
cooldown is complete, the Lamp Indicator will change
to red.
3
Initiate Shutdown
Once both the AC-mains and Lamp Indicator LEDs
have changed to red, you can remove the AC-mains
power from the Auditorium Unit. Removal of UPS
AC-mains triggers an automatic shutdown of the
Media Block, the SMS Server and finally the UPS.
Shutdown from Menu
To access System
Shutdown, tap
Menu
, tap
Restart SMS Server
and
then tap
System
Shutdown
. A
confirmation message
appears. Tap
YES
to
initiate the Shutdown
process.
Once Shutdown has been
confirmed there is no
way to abort the process.
The Shutdown process
can take an extended period of time if initiated while the
Lamp is ON. This delay is because of the requirement for
cool down of the Projection Lamp. Once the Projector
enters STANDBY mode, (Lamp cooldown has
completed
1
) the SMS Server initiates the sequenced
shutdown process, i.e., Media Block, UPS (delayed
shutdown command which allows for shutdown of the
SMS Server), and the SMS Server.
Note
1.It can take up to 20 minutes for the Lamp cool down
cycle to complete if System Shutdown is executed directly
from Lamp ON mode.
Tap Restart SMS Server
Restart SMS Server Menu