14. Attach the top cover assembly. (Refer to
Note
• Be sure to attach the top cover assembly.
• Do not turn on the power with the top cover assembly removed.
• If the power is turned on with the top cover assembly removed, it may cause injury, electrical shock or disorder
due to the laser light.
• Route the two flexible flat cables that are not connected in step 13 to the outside of the top cover assembly.
Care should be taken because if the cable enters inside of the assembly, it may cause a short circuit of power
supply.
PP-61 board
PP-61 board
Flexible flat cables
Top cover assembly
15. Turn on the power of this unit.
16. Display the maintenance menu referring to
“6-2. Starting the Maintenance Menu”
17. Move the cursor to “CHECK” using [UP]/[DOWN] buttons.
18. Press the [RIGHT] button.