Code
Description
Error remedy method
Refer to section
4D-901
The 5V-SAG detection func-
tion was activated disabling
the system to start. (On side
1)
1.
Check the power cable connection.
• Check the power cable for firm con-
nection and damage.
• When the power cable is properly con-
nected, unplug and plug it and then
check whether this situation is im-
proved.
2.
Check the power supply to the unit for fluc-
tuation.
Note
If a high-power device is connected to the
same power channel as this unit, power sup-
ply voltage may be unstable depending on
the startup or operation of the device. In this
case, connect the power of this unit inde-
pendently and then check whether this situa-
tion is improved.
3.
Check the PP-61 board installation status.
4.
Check the flexible flat cable connection be-
tween PP-61 board and BI-353 board (ODS-
D280U)/BF-92 board (ODS-D280F).
• Improper connection (half insertion or
oblique insertion)
• Damage to connectors
• Significant scratches or disconnection
of flexible flat cables
• Damage or contamination at connect-
ing parts (Unplug flexible flat cables.)
5.
Check the main base assembly installation
status.
“4-19. BI-353/BF-92 Board”
“4-20. PP-61 Board”
“4-29. Sub Base Assembly”
2-2-4.
Error 5X Error Remedy Method
Code
Description
Error remedy method
Refer to section
50-010
BCA area data cannot be
read.
1.
Eject a cartridge.
2.
Insert another cartridge.
• In the case no error occurs:
The ejected cartridge is likely to be
faulty.
• In the case the error occurs:
A drive fault is likely.
―
50-011
BCA area data is invalid.
1.
Eject a cartridge.
2.
Insert another cartridge.
• In the case no error occurs:
The ejected cartridge is likely to be
faulty.
• In the case the error occurs:
A drive fault is likely.
―
51-020
PIC area data cannot be read.
1.
Eject a cartridge.
2.
Insert another cartridge.
• In the case no error occurs:
The ejected cartridge is likely to be
faulty.
• In the case the error occurs:
A drive fault is likely.
―
51-021
PIC area data is invalid.
1.
Eject a cartridge.
2.
Insert another cartridge.
• In the case no error occurs:
The ejected cartridge is likely to be
faulty.
• In the case the error occurs:
A drive fault is likely.
―
Continued
ODS-D280U/ODS-D280F
2-58
sub
Содержание ODS-D280F
Страница 4: ......
Страница 9: ...Frame Wiring 10 3 Revision History ODS D280U ODS D280F 5 ...
Страница 10: ......
Страница 12: ......
Страница 42: ...Hold the shaded portions Keep away a screwdriver Objective lens Actuator ODS D280U ODS D280F 1 30 ...
Страница 158: ......
Страница 238: ......
Страница 248: ...Possible cause A cartridge is remaining in the unit ODS D280U ODS D280F 6 4 ...
Страница 274: ......
Страница 278: ......
Страница 300: ......
Страница 304: ......
Страница 306: ......
Страница 307: ......