72
Replacement Procedures when IP Converter Fault Occurs
7
Activate the workgroup.
“Changing a Network GenLock Leader Device” (page 68)
Changing a Network InputLock Device
1
Deactivate the workgroup.
“Changing a Network GenLock Leader Device” (page 68)
2
Select the [Default Network InputLock Group] in which a fault has occurred on the [Network InputLock Group List]
screen, and click the [Assign Members] button.
The [Assign Virtual Network InputLock Module] dialog appears.
3
Select the IP converter on which a fault has occurred, and click the [Delete] button.
The selected IP converter is deleted from the [Virtual Network InputLock Module List].
4
Select a new IP converter in the [GenLock Module List], and click
.
The new IP converter is registered in the [Virtual Network InputLock Module List].