173
Menu List
App
end
ix
613
TC OUTPUT
SIGNAL IN
REGENE MODE
[off tape]
regene
through
Specifies the signal output to the TIME CODE OUT
connector when the internal time code generator is in a
mode for regenerating the playback time code (i.e. during
auto edit mode or when item 607 is set to “int-LTC” and
item 606 is set to “regene”).
off tape: The playback time code signal is output to the
TIME CODE OUT connector without regeneration.
regene: The playback time code signal is output to the
TIME CODE OUT connector after regeneration only
when the VTR is in playback mode.
through: The time code signal input to the TIME CODE IN
connector is output as it is.
614
PHASE
CORRECTION
[off]
on
Specifies whether the phase correction control of the LTC
signal generated by the time code generator is applied or
not.
off: The phase correction control is not applied.
on: The phase correction control is applied.
616
VITC POSITION-1
select (PAL)
9,322 line
[19,332 line]
22,335 line
When 25PsF/50i mode is selected on the VTR, this setting
specifies the lines in which the VITC signal is inserted.
It can be inserted in any lines from 9,322 to 22,335.
Note
Items 616 and 617 allow VITC to be inserted in two lines.
617
VITC POSITION-2
select (PAL)
9,322 line
[21,334 line]
22,335 line
When 25PsF/50i mode is selected on the VTR, this setting
specifies the lines in which the VITC signal is inserted.
It can be inserted in any lines from 9,322 to 22,335.
Note
Items 616 and 617 allow VITC to be inserted in two lines.
618
LTC OUTPUT
PHASE select
input
auto
[output]
Selects the LTC output phase.
input: Same phase as input video.
auto: When editing, same phase as input video; otherwise
(playback, recording, etc.), same phase as output
video.
output: Same phase as output video.
619
EXT LTC MODE
direct
[regene]
Selects the recording mode when the internal time code
generator is set to regenerate the input from the TIME
CODE IN connector (menu item 607 is set to “ext-LTC”, and
menu item 606 is set to “regene”).
direct: Records the time code input from the TIME CODE
IN connector unaltered on the tape.
regene: Regenerates the time code input from the TIME
CODE IN connector with the internal time code
generator.
620
SUPERIMPOSED
CHARACTER
[off]
on
Specifies whether or not to superimpose time data and
operating status information on the signal output from the
MONITOR connector of SD SDI OUT, the SD OUT
COMPOSITE connector and MONITOR connector of HD
SDI OUTPUT.
off: No information is superimposed.
on: Information is superimposed.
622
CHARACTER H-
POSITION
0
[8]
15
Sets the horizontal position of text information
superimposed on the signal output from the MONITOR
connector of SD SDI OUT, the SD OUT COMPOSITE
connector and MONITOR connector of HD SDI OUTPUT. A
setting of 0 displays the information at the left edge of the
screen, and the position moves to the right as the setting is
increased. There are 16 possible settings, from 0 to 15.
Item number
Item
Setting
Function
Содержание HKSR-5803HQ
Страница 211: ...Sony Corporation SRW 5800 SY 3 286 523 06 1 2007 ...